Operating
5.2.2 Releasing the load
•
Lower the load to a safe and clear, level surface, to ensure that the load cannot slip or tip over.
Shift the bushing on the slide valve (6) back. The load is released.
5.2.3 Lifting wet loads
•
The lifting device is not intended for picking up wet stone slabs. When picking up wet stone slabs, please
observe the following:
•
Remove water from the suction surface.
•
Carry out the following points after working with damp parts:
•
Lift up the lifting device. Make sure that the area around the suction plate is clear and that no items or water
can be drawn in.
•
Let the pump idle to run dry for at least 5 minutes.
•
Then switch off the device.
•
Open the condensate drain screw on the bottom of the storage container. Drain the water completely and
tighten the drain screw securely.
•
Open the condensate drain screw on the bottom of the storage container.
•
Drain the water completely and tighten the drain screw securely again.
52400020
Condensate drain
screw
25 / 31