BRINKMANN PUMPS BAL901 Operating Instructions Manual

BRINKMANN PUMPS BAL901 Operating Instructions Manual

Horizontal end suction pumps

Advertisement

Quick Links

BRINKMANN-Horizontal End Suction Pumps
BAL/SBA901...1303, BGL/SBG801...1103 and
BFL/SBF650...1150
Brinkmann Pumpen
K. H. Brinkmann GmbH & Co. KG
Friedrichstraße 2
D-58791 Werdohl
Tel.: +49-2392 / 5006-0
Fax.: +49-2392 / 5006-180
Subject to change without prior notice.
© Brinkmann Pumpen
BE8100 Operating Instructions
(Translation of original)
Edition
www.brinkmannpumps.de
sales@brinkmannpumps.de
Order - No.: BE8100 ENGLISH
06/2024
1 of 12
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BAL901 and is the answer not in the manual?

Questions and answers

Summary of Contents for BRINKMANN PUMPS BAL901

  • Page 1 BE8100 Operating Instructions (Translation of original) BRINKMANN-Horizontal End Suction Pumps BAL/SBA901...1303, BGL/SBG801...1103 and BFL/SBF650...1150 Brinkmann Pumpen K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Tel.: +49-2392 / 5006-0 www.brinkmannpumps.de Fax.: +49-2392 / 5006-180 sales@brinkmannpumps.de Subject to change without prior notice. Order - No.: BE8100 ENGLISH ©...
  • Page 2: Table Of Contents

    Brinkmann–Horizontal End Suction Pumps Series BAL/SBA901...1303, BGL/SBG801...1103 and BFL/SBF650...1150 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2 10 Spare part ............8 Safety instructions ..........3 11 Repair Instructions ........... 9 Transport and storage ........
  • Page 3: Safety Instructions

    S... 50 / 60 Hz level bar / spec. Type / B... Type / S... weight 1 l/min H mm h mm l mm dBA / 50 Hz BAL901 SBA901 1100 BAL902 SBA902 1150 BAL903 SBA903 1200 10.3 BAL1301 SBA1301 1350 5.75...
  • Page 4: Transport And Storage

    Safety instructions relevant for operation 5 Installation and Connection • If hot or cold machine components involve Mechanical installation hazards, they must be guarded against acci- The pumps must be properly fastened. The pipe- dental contact. work must be installed so that no distortion of the •...
  • Page 5: Start Up / Shut Down

    Wiring diagram e.g. ATTENTION Maximum tightening torque for piping connections is 170 Nm! Star connection When installed the space around the pump must up to 5.5 kW be large enough to provide sufficient cooling of 3 x 400 V, 50 Hz the motor.
  • Page 6: Operation

    7 Operation Liquid level These pumps are not self-priming and must be gravity fed. Possible leakage must be drained away so as to prevent any risk to persons or the environment. Screw plug Leakage G 1/8 Oil inspection window execution-GD only. ATTENTION The BFL/SBF pump should be operated in contin- ual operation mode, not pulsed mode!
  • Page 7: Servicing And Maintenance

    8 Servicing and Maintenance Pumps with double mechanical seal (-GD) Pumps with double mechanical seal (-GD) are ATTENTION identified by the letters GLRD stamped in on the motor side of the pump foot and must include an oil The surface of the motor must be kept free of dirt. receiver with a capacity of 0.65 litres.
  • Page 8: Spare Part

    10 Spare part 10.1 Spare part list for Brinkmann Horizontal BAL/SBA901...1303, BGL/SBG801...1103 and End-Suction Pumps Series BFL/SBF650...1150 Item Description Item Description Stator with terminal board 28 Sealing ring DIN 7603 Motor flange 29 O-ring End shield 30 Shaft seal Terminal box up to 5.0 kW 31 Compensation disk 4.1 Terminal box frame up 6.0 kW 50 Pump body...
  • Page 9: Repair Instructions

    10.2 Indications to the spare part order The mechanical seal (24) should now be com- Spare parts are available from the supplier. pletely replaced. If necessary replace the O- Standard commercially available parts are to be rings (67), (78) and impellers (55, 56). purchased in accordance with the model type.
  • Page 10: Disposal

    11.2 Dismantling the insert shaft 12) Mount the pump foot and the pump body. The remainder of the reassembly process is to be completed in the opposite order of the prior de- scribed dismantling process. ATTENTION Note torques for the screw connections! 1 = Shaft clamp 2 = Insert shaft 13) Position the pump laterally and fill the pump...
  • Page 11: Eclarations Of Conformity

    Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Horizontal End-Suction Pumps BAL/SBA901…1303, BGL/SBG801…1103, BFL/SBF650…1150...
  • Page 12 13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Blockpumpen / Horizontal End-Suction Pumps / Pompes horizontales monobloc / Bombas horizontales monobloc...

Table of Contents