Brinkmann Immersions pumps of the series STA/SAL1005 ... 1006 Contents 9 Trouble shooter’s guide ........6 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............7 Safety instructions .......... 3-4 11 Repair ............... 8 Transport and storage ........
Technical data Max. del. Max. del. Height Depth of Weight Power Noise pressure bar / volume immersion 60 Hz level 1, 2) Type Type spec. weight 1 l/min H mm h mm g kg dBA / 50 Hz STA1005 / 530 10.8 1450 15/17.3...
Safety instructions relevant for mainte- nance, inspection and assembly work Any work on the machine shall only be performed when it is at a standstill, it being imperative that the procedure for shutting down the machine described in this manual be followed. Pumps and pump units which convey hazardous media must be decontaminated.
5.2.1 Circuit Tension voltage and frequency must correspond with the shown specification on the nameplate. The pump must be wired so that a solid longterm electrical connection is ensured. Establish a solid ground connection. The electrical wiring must be performed accord- ing to the wiring diagram shown inside the terminal box cover.
8 Servicing and Maintenance ATTENTION The surface of the motor must be kept free of dirt. The motor shaft is spinning in permanently greased ball bearings (with special grease and increased bearing play) and does not require any special maintenance. 9 Trouble shooter’s guide Fault Cause...
10 Spare part 10.1 Spare part list for the immersion pumps of the series STA/SAL1005 ... 1006 Item Description Motor Bearing housing Woodruff key DIN 6888 Bearing shaft Ball bearing DIN 628 Socket head cap screw DIN 912 Bearing cover Coupling 10 Nilos-ring 11 Threaded pin...
11.2 Assembling the insert shaft and motor 10.2 Indications to the spare part order shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. Clean the contact surfaces of the insert shaft (2) The ordering of spare parts should contain the (inside) and the motor shaft (3).
13 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?
Do you have a question about the STA1005 Series and is the answer not in the manual?
Questions and answers