RELIANCE Inset Lights
12-inch (RC-RZ-RX-RE-RT-RW-RN-RTN-AC-AS-SW-RS-TC-SB)
User Manual
UM-0210, Rev. 4.1, 2022/11/28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RELIANCE RC and is the answer not in the manual?

Questions and answers

Summary of Contents for ADB Safegate RELIANCE RC

  • Page 1 RELIANCE Inset Lights 12-inch (RC-RZ-RX-RE-RT-RW-RN-RTN-AC-AS-SW-RS-TC-SB) User Manual UM-0210, Rev. 4.1, 2022/11/28...
  • Page 3 Material Handling Precautions and Storage precautions that must be followed. ADB SAFEGATE reserves the right to examine goods upon which a claim is made. Said goods must be presented in the same condition as when the defect therein was discovered. ADB SAFEGATE furthers reserves the right to require the return of such goods to establish any claim.
  • Page 4 This manual could contain technical inaccuracies or typographical errors. ADB SAFEGATE BV reserves the right to revise this manual from time to time in the contents thereof without obligation of ADB SAFEGATE BV to notify any person of such revision or change. Details and values given in this manual are average values and have been compiled with care. They are not binding, however, and ADB SAFEGATE BV disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers.
  • Page 5: Table Of Contents

    7.12 Spare Parts (AS) ........................................49 7.13 Ordering Code (SW) ......................................51 7.14 Spare Parts (SW) ........................................53 7.15 Ordering Code (RS) ......................................55 7.16 Spare Parts (RS) ........................................57 UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 6 A.0 INTEROPERABILITY ................................71 B.0 POWER TABLE ..................................73 C.0 CABLE LOSS ..................................81 D.0 SUPPORT ....................................83 D.1 ADB SAFEGATE Website ...................................... 83 D.2 Recycling ............................................ 83 D.2.1 Local Authority Recycling ..................................83 D.2.2 ADB SAFEGATE Recycling ..................................84...
  • Page 7 Figure 25: Converter with 1 connector ................................... 26 Figure 26: Converter with 2 connectors ..................................26 Figure 27: Converter with 1 connector ................................... 27 Figure 28: Converter with 2 connectors ..................................27 UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 8 RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate, All Rights Reserved ©...
  • Page 9 List of Tables Table 1: Bidirectional light beam ....................................... 16 Table 2: Unidirectional light beam ....................................16 Table 3: Maintenance tasks ......................................... 19 Table 4: Interoperability matrix ......................................71 UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 10 RELIANCE Inset Lights List of Tables Copyright ADB Safegate, All Rights Reserved ©...
  • Page 11: Safety

    1.0 Safety Introduction to Safety This section contains general safety instructions for installing and using ADB SAFEGATE equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate.
  • Page 12: Introduction To Safety

    Using this equipment in ways other than described in this manual may result in personal injury, death or property and equipment damage. Use this equipment only as described in this manual. Failure to follow this instruction can result in serious injury or equipment damage Copyright ADB Safegate, All Rights Reserved ©...
  • Page 13: Material Handling Precautions: Storage

    Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component according to instructions provided in its manual. Failure to follow these instructions can result in death or equipment damage UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 14: Material Handling Precautions: Fasteners

    Note To minimize the risk of errors, the ADB SAFEGATE Sales Representative will have information on which gasket goes with which base. This information is also provided in the product Data sheets, the User Manuals and the Spare Part Lists.
  • Page 15: About This Manual

    Taxiway Centerline Narrow L-852C(L) (TC) • Taxiway Centerline Curve L-852K(L) (TC) • Taxiway Centerline Wide (TC) • Taxiway Centerline/Lead-On L-852D(L) (TC) • ICAO Stop Bar (SB) • FAA Stop Bar (SB, L-852S(L) UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 16: How To Work With The Manual

    Individual Light Control and Monitoring System Light Emitting Diode NATO North Atlantic Treaty Organization SMGCS Surface Movement Guidance and Control System System Switch Unit STAC Service Technique de l'Aviation Civile (France) STANAG Standardization Agreement (NATO) Copyright ADB Safegate, All Rights Reserved ©...
  • Page 17: Introduction

    RELIANCE with integrated fail-open (Mon) technology. Fuse resistors are part of the Mon-functionality and spares needs to be ordered separately. • RELIANCE Non-MON, non-monitored lights • Light Emitting Diode (LED) technology that offers a long-lasting light source with low power consumption UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 18: Dimensions And Weight

    RC – RZ – RX – RE – RT – RN – SW – RS – TC – SB 6.3 kg / 13.9 lb 85 mm / 3.3-in Notes Compatible with ICAO Compatible with FAA Copyright ADB Safegate, All Rights Reserved ©...
  • Page 19 12-inch UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 20 RELIANCE Inset Lights Introduction Copyright ADB Safegate, All Rights Reserved ©...
  • Page 21: Installation

    If the inset light fixture is to be installed on another type of base or adapter ring not provided by ADB SAFEGATE, contact ADB SAFEGATE. The inset light fixture is fixed in the base by six M10 lock nuts or by six M10×25 or M10×22 bolts dependent on base installation.
  • Page 22: Tools Required

    3. Connect the connector(s) of the light fixture to the base supply cable(s). Check that the sides 1 and 2 are connected to corresponding circuit if two connectors are used. 4. Align the position of the light fixture in one line with the holes. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 23: Toe-In

    The following chapter only regards the case where light fixtures are installed in runway/taxiway parallel bases, i.e. where no toe-in is achieved by angled bases. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 24: Figure 4: Toe-In

    ± 15.75 ˚ Optical Taxiway Centerline Wide (TC-I) Straight L-852D(L) -Taxiway Centerline/Lead-On (TC-I) Straight L-852S(L) & ICAO Stop Bar (SB-I) Straight or Toe-in ± 15.75 ˚ Optical Notes Toe-in only affects the green threshold side. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 25: Light Emission Directions

    The inset Taxiway centerline and Stop Bar light fixtures have different light beam characteristics depending on application. The light beam can be narrow, wide or curved. The drawings below show the different types of light beam, which correspond to the different type of fitting. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 26: Table 1: Bidirectional Light Beam

    ICAO Fig A2-12 FAA L852C(L) FAA L852D(L) FAA L852K(L) Table 2: Unidirectional light beam Straight Toe-in Narrow Wide Wide Curved ICAO Fig A2-13 ICAO Fig A2-12 FAA L852C(L) FAA L852D(L), L-852S(L) FAA L852K(L) Right Left Copyright ADB Safegate, All Rights Reserved ©...
  • Page 27: Operation

    5.0 Operation Note Refer to the UM-0600 and other documentation related to RELIANCE IL I and listed with ordering numbers in Data sheet DS-0600 for further info. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 28 RELIANCE Inset Lights Operation Copyright ADB Safegate, All Rights Reserved ©...
  • Page 29: Maintenance

    Spare parts are available, if required. For more information, see www.adbsafegate.com and the Spare Parts List document, or contact ADB SAFEGATE for assistance. CAUTION Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and create multiple safety risks.
  • Page 30: Open And Close A 12-Inch Fixture

    2. Lift up the housing and disconnect the LED board cable connector from the LED boards in the top cover, see Figure Note Open the light fixture cautiously, be careful not to damage the LED-board cables. Depending on type and size of nuts and bolts Copyright ADB Safegate, All Rights Reserved ©...
  • Page 31: Figure 7: Fixture Upside Down

    INTEROPERABILITY. Figure 10: Converter with 1 connector Figure 11: Converter with 2 connectors 4. Put the light fixture on a surface with the top cover facing down, see Figure UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 32: Check The Light Fixture For Water-Tightness

    2. The light fixture is ready to be reinstalled in the field. DANGER Never exceed pressure of 150 kPa inside the light fixture as this may lead to personal injuries and damage the light. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 33: Replace A Light Engine In A 12-Inch Fixture

    Remove 1. Disassemble the light fixture. 2. Detach and remove the LED board holder, including 4 screws from the body, using a 4 mm Allen key, see [fig 1.x]. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 34: Figure 17: Remove Led Board Holder

    6. Looking from above, make sure the prism edge is parallel with the prism holder, see Figure Figure 20: Prism holder edge 7. Use non-alcohol based cleaner to remove any grease or dust from the prism. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 35: Replace The Bottom Cover And Converter

    1. Place the new gasket on the new bottom cover with converter. 2. Connect the LED board cable(s). Note the orientation and alignment of the cables in Figure 22 Figure UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 36: Reset The Fail-Open Converter 2.3

    2. Place the 2-way electrical shunt (2.54 mm spacing) over the two pins marked red, see Figure 25 Figure Figure 25: Converter with 1 connector Figure 26: Converter with 2 connectors 3. Close the light fixture and connect it to a CCR. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 37: Reset The Fail-Open Converter 48010921 And 48011111

    If both A and B channel needs a reset, replace all 4 fuse resistors. 4. Dispose the old fuse resistor. 5. Place the legs of the new fuse resistors in the sockets. 6. Assemble the light fixture and perform a functional test. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 38 RELIANCE Inset Lights Maintenance Copyright ADB Safegate, All Rights Reserved ©...
  • Page 39: Ordering Codes And Spare Parts

    7.0 Ordering Codes and Spare Parts Spare parts are available for RELIANCE and RELIANCE IQ inset light fixtures. For more information, see www.adbsafegate.com and the spare part lists, or contact ADB SAFEGATE for assistance. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved...
  • Page 40: Ordering Code (Rc-Rz-Rx)

    G = Global (RC, RZ) Cord set type A = FAA Style 6 (2 - pin-) plug Cable and connector 2 = 1x 2-pin plug 3 = 2x 2-pin plugs Version 3 = RELIANCE Copyright ADB Safegate, All Rights Reserved ©...
  • Page 41: Spare Parts (Rc-Rz-Rx)

    This function is disabled in IQ0 fixtures but could be enabled later. IQ light fixtures are only available as a one connector option. 7.2 Spare Parts (RC-RZ-RX) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code...
  • Page 42 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 43: Ordering Code (Re)

    Cable and Connector 2 = 1x 2-pin plug 3 = 2x 2-pin plug (for bidirectional) 4 = 1x 3-pin plug 5 = 2x 3-pin plug (for bidirectional) Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 44: Spare Parts (Re)

    • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. 7.4 Spare Parts (RE) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting...
  • Page 45 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 46: Ordering Code (Rw)

    This function is disabled in IQ0 fixtures but could be enabled later. IQ light fixtures are only available as a on e connector option. • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 47: Spare Parts (Rt)

    7.6 Spare Parts (RT) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, unidirectional 1 prism SGE.SP18494 (L-850D) Top plate, unidirectional 2 prisms (F- SGE.SP18539 green) Top plate, unidirectional 3 prisms (G- SGE.SP18551...
  • Page 48 Note Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 49: Spare Parts (Rw)

    7.7 Spare Parts (RW) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate unidirectional 3 Prism, SGE.SP18551 Straight Top plate unidirectional 3 Prism, SGE.SP18552 Left Top plate unidirectional 3 Prism, SGE.SP18553...
  • Page 50 Note Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 51: Ordering Code (Rt-Rn)

    Cable and Connector 2 = 1x 2-pin plug 3 = 2x 2-pin plug (for bidirectional) 4 = 1x 3-pin plug 5 = 2x 3-pin plug (for bidirectional) Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 52 This function is disabled in IQ0 fixtures but could be enabled later. IQ light fixtures are only available as one connector option in an ILCMS. • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 53: Spare Parts (Rt-Rn)

    7.9 Spare Parts (RT-RN) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, bidirectional straight SP.012973 Top plate, unidirectional straight SP.012974 Top plate, bidirectional straight (2+1 SGE.SP18550 window) Prism incl. prism gasket, protection plate SGE.SP18497...
  • Page 54 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 55: Ordering Code (Ac-As)

    A = Style 6 2-pin plug F = Flat 3-pin plug (French, for ICAO only) Cable and connector 2 = 1x 2-pin plug 4 = 1x 3-pin plug Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 56 This function is disabled in IQ0 fixtures but could be enabled later. IQ light fixtures are only available as a one connector option. • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 57: Spare Parts (Ac)

    7.11 Spare Parts (AC) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate unidirectional 3- SGE.SP18551 Prism, Straight Top plate unidirectional SGE.SP18552 3 Prism, Left Top plate unidirectional SGE.SP18553 3 Prism, Right Prism incl.
  • Page 58 Note Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 59: Spare Parts (As)

    7.12 Spare Parts (AS) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate unidirectional SGE.SP18570 2-prism, Left Top plate unidirectional 2- SGE.SP18569 prism, Right Top plate unidirectional 2- SGE.SP18539 prism, Straight Prism incl.
  • Page 60 Note Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 61: Ordering Code (Sw)

    Q = 2.8 - 6.6 A/ 2 A, IQ1 (IQ enabled) Standards M = ICAO and MOS Cord Set Style A = Style 6 (2 -pin) plug Cable and Connector 2 = 1x 2-pin plug Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 62 The IQ functionality allows control and monitoring of the RELIANCE IQ. IQ1 fixtures are pre - configured for the specific position at delivery. This function is disabled in IQ0 fixtures but can be enabled later. • IQ light fixtures are only available as a one connection option. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 63: Spare Parts (Sw)

    7.14 Spare Parts (SW) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, unidirectional straight SP.012974 Prism incl. prism gasket, protection plate and prism SGE.SP18497 holder Reinforced prism incl. prism gasket, protection plate and SGE.SP18498...
  • Page 64 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 65: Ordering Code (Rs)

    Q = 2.8 - 6.6 A/ 2 A, IQ1 (IQ enabled) Standards F = FAA AC 150/5345-46D Cord set type A = Style 6 (2-pin) plug Cable and connector 2 = 1x 2-pin plug Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 66 The IQ functionality allows control and monitoring of the RELIANCE IQ. IQ1 fixtures are pre - configured for the specific position at delivery. This function is disabled in IQ0 fixtures but could be enabled later. • IQ light fixtures are only available as a one connector option. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 67: Spare Parts (Rs)

    7.16 Spare Parts (RS) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting code Top plate, unidirectional straight SP.012974 Prism incl. prism gasket, protection plate and prism SGE.SP18497 holder Reinforced prism incl. prism gasket, protection plate and SGE.SP18498...
  • Page 68 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 69: Ordering Code (Tc)

    F = Flat 3-pin plug (French, only for ICAO) Cable and connector 2 = 1x 2-pin plug 3 = 2x 2-pin plug 4 = 1x 3-pin plug 5 = 2x 3-pin plug Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 70 Narrow color combinations : FF, FY, YF, YY, FN and YN • Curved (C,R,L,D) color combinations : FF, YY, FN, and YN • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 71: Spare Parts (Tc)

    7.18 Spare Parts (TC) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, bidirectional straight SP.012973 Top plate, unidirectional straight SP.012974 Prism incl. prism gasket, protection plate SGE.SP18497 and prism holder Reinforced prism incl.
  • Page 72 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 73: Ordering Code (Sb)

    F = Flat 3-pin plug Cable and connector 2 = 1x 2-pin plug 3 = 2x 2-pin plug 4 = 1x 3-pin plug 5 = 2x 3-pin plug Version 3 = RELIANCE UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 74 Q = 2.8 - 6.6 A/ 2 A, IQ1 (IQ enabled) Standards F = FAA AC 150/5345-46E Cord set type A = Style 6 (2-pin) plug Cable and connector 2 = 1x 2-pin plug Version 3 = RELIANCE Copyright ADB Safegate, All Rights Reserved ©...
  • Page 75 • IQ light fixtures are only available with connector option 2. • A 3-pin cable and connector are only available for the ICAO standard regardless of the color combination. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 76: Spare Parts (Icao Sb)

    RELIANCE Inset Lights Ordering Codes and Spare Parts 7.20 Spare Parts (ICAO SB) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, bidirectional straight SP.012973 Top plate, unidirectional straight SP.012974...
  • Page 77 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 78: Spare Parts (Faa Sb)

    RELIANCE Inset Lights Ordering Codes and Spare Parts 7.21 Spare Parts (FAA SB) Note Contact ADB SAFEGATE for assistance with ordering spare parts, www.adbsafegate.com. Quantity per Description Order code fitting order Top plate, unidirectional straight SP.012974 Prism incl. prism gasket, protection plate SGE.SP18497...
  • Page 79 All screws for fastening are included. Component availability or design may be subject to change due to unforeseen circumstances. This document is subject to change or new information from ADB SAFEGATE, as and when available or if required, with reservation for error or price changes.
  • Page 80 RELIANCE Inset Lights Ordering Codes and Spare Parts Copyright ADB Safegate, All Rights Reserved ©...
  • Page 81: Table 4: Interoperability Matrix

    Only with non-roll over lights Do not use Loctite or washer with self-locking nut Note Version 1 with the code ending with 1, please ask your local sales representative for base compatibility. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 82: Interoperability

    RELIANCE Inset Lights INTEROPERABILITY Copyright ADB Safegate, All Rights Reserved ©...
  • Page 83: Power Table

    8 VA 11 VA 29 VA 29 VA L-850A(L), White/White Runway Centerline, 18 VA 13 VA 25 W 25 W 8 VA 11 VA 29 VA 24 VA L-850A(L), White/Red UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 84 LED Runway Threshold Wingbar Isolation transformer Fixture type - 1 cord set Fixture load CCR load Rating Loss Efficiency Runway Threshold Wingbar, ICAO, F-Green 64 VA 65 W 11 VA 0.85 75 VA Copyright ADB Safegate, All Rights Reserved ©...
  • Page 85 Fixture type – 1 cord set Fixture load CCR load Rating Efficiency Energy Use Runway Status, Take off, Intersection 20 VA 25 W 11 VA 31 VA L-850T(L), Red UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 86 22 VA 25 W 11 VA 33 VA Taxiway Centerline Wide, Yellow/G-Green 30 VA 45 W 0.85 8 VA 38 VA Taxiway Centerline Wide, Blue/Blue 23 VA 25 W 11 VA 34 VA Copyright ADB Safegate, All Rights Reserved ©...
  • Page 87 11 VA 11 VA 22 VA 22 VA Yellow/F-Green Taxiway Centerline Wide, 14 VA 11 VA 25 W 25 W 11 VA 11 VA 22 VA 22 VA Yellow/G-Green UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 88 Energy Use cord sets, 25° C B-side A-Side B-Side A-Side B-side A-Side B-Side A-Side B-Side A-Side Stopbar, Red/Red 14 VA 14 VA 25 W 25 W 11 VA 11 VA 25 VA 25 VA Copyright ADB Safegate, All Rights Reserved ©...
  • Page 89 • If part of a Reliance 2A system: The data provided in the above table(s) is not applicable if part of a 2A reliance system. In this case, please contact your local ADB Safegate representative. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 90 RELIANCE Inset Lights POWER TABLE Copyright ADB Safegate, All Rights Reserved ©...
  • Page 91: Cable Loss

    For a primary cable of e.g., 100 m of 6 mm CU-wire, 100 m × 0.12 W/m = 12 W equals the additional loss to be taken into account. UM-0210, Rev. 4.1, 2022/11/28 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 92 RELIANCE Inset Lights CABLE LOSS Copyright ADB Safegate, All Rights Reserved ©...
  • Page 93: Support

    D.2.1 Local Authority Recycling The disposal of ADB SAFEGATE products is to be made at an applicable collection point for the recycling of electrical and electronic equipment. The correct disposal of equipment prevents any potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling.
  • Page 94: Adb Safegate Recycling

    Main Unit Serial Number. ADB SAFEGATE will continue to monitor and update according for any future requirements for EU directives as and when EU member states implement new regulations and or amendments. It is our aim to maintain our compliance plan and assist our customers.
  • Page 95 Tel.: +46 (0)40 699 17 00 Internet: www.adbsafegate.com Fax: +46 (0)40 699 17 30 ADB SAFEGATE, China ADB SAFEGATE Airfield Technologies Ltd. China Unit 603, D Block, CAMIC International Convention Center, No 3, Hua Jia Di East road, ChaoYang district, Beijing 100102 P.R.