High intensity unidirectional elevated light for approach, threshold and runway end and for sequenced flashing lights (sfls), runway threshold identification (rtils) systems
Runway inset lights 12-inch and 8-inch (rc-rz-re-rn-rt-rs-ts-r6-sw-s6-rw) (88 pages)
Summary of Contents for ADB Safegate UEL-1-150
Page 1
High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Runway Threshold Identification (RTILS) Systems User Manual UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19...
Page 3
Material Handling Precautions and Storage precautions that must be followed. ADB SAFEGATE reserves the right to examine goods upon which a claim is made. Said goods must be presented in the same condition as when the defect therein was discovered. ADB SAFEGATE furthers reserves the right to require the return of such goods to establish any claim.
Page 4
This manual could contain technical inaccuracies or typographical errors. ADB SAFEGATE BV reserves the right to revise this manual from time to time in the contents thereof without obligation of ADB SAFEGATE BV to notify any person of such revision or change. Details and values given in this manual are average values and have been compiled with care. They are not binding, however, and ADB SAFEGATE BV disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers.
1.0 Safety Introduction to Safety This section contains general safety instructions for installing and using ADB SAFEGATE equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate.
• Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks. • Only persons who are properly trained and familiar with ADB SAFEGATE equipment are permitted to service this equipment. • An open airfield current circuit is capable of generating >5000 Vac and may appear OFF to a meter.
2.0 About this Manual This manual describes the procedures for installation, maintenance and troubleshooting of the ADB SAFEGATE type UEL lights. This manual covers the light fixtures suitable for use in systems described in ICAO Annex 14, Attachment A, Section 11 .
3.2 Product data 3.2.1 Equipment supplied UEL units are either packed individually in a durable, cushioned and corrugated cardboard box, labeled with ADB SAFEGATE and ordering numbers, or on pallet boxes in larger quantities. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19...
4.2.2 Electrical connection • The UEL-1-150 light assemblies are designed for connection to 6.6 or 20 Amps series circuits via one FAA L-830 or L-831 isolation transformer (type ADB : RST), with a nominal secondary current of 6,6A. Refer to ADB cat. leaflet A.06.110 or Instruction manual AM.06.110 for more information on isolation transformers.
Page 17
The following table instructs you on how to install the UEL-1-150 at ground level: a) Before installing the light, connect the plug of the two-core cable to the receptacle of the cable coming from the transformer. Note The transformer receptacle rests in the upper part of the conduit elbow or the cover plate.
1. UEL-1-150 steady burning light The following table instructs you on how to install the UEL-1-150 on a 60 mm O.D. conduit: a) Before installing the light, prepare a two-core cable with plug, making sure that a sufficient length of cable is available above the conduit elbow or cover plate.
Page 22
High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Installation The following table instructs you on how to install the UEL-1-150 on a safety approach mast: a) Before installing the light, install a two-core secondary cable from the transformer to the top of the mast, according to the instructions of the manufacturer of the mast.
1. Open the fitting by hinging down the optical cartridge (1). 2. (UEL-1-150): Slide the insulating sleeves away from the "fast-on" connectors and disconnect the lamp (2) from the cable wires.
Defective isolation transformer Check transformer secondary current (in short-circuit) with true RMS Ammeter. Short lamp life (UEL-1-150): Too high current (lamp will have black Check output current of isolating transformer at full burns) brightness. Current should not exceed 6.7 A.
High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Assemblies and Exploded Views 8.2.3 Spare Parts and numbers In the table below you will find all parts of the UEL-1-150 and UEL-1-120 lights. References related to exploded view UEL White...
A.2.1 Local Authority Recycling The disposal of ADB SAFEGATE products is to be made at an applicable collection point for the recycling of electrical and electronic equipment. The correct disposal of equipment prevents any potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling.
Main Unit Serial Number. ADB SAFEGATE will continue to monitor and update according for any future requirements for EU directives as and when EU member states implement new regulations and or amendments. It is our aim to maintain our compliance plan and assist our customers.
Page 41
Tel.: +46 (0)40 699 17 00, Internet: www.adbsafegate.com Fax: +46 (0)40 699 17 30 ADB SAFEGATE Airfield Technologies Ltd. China ADB SAFEGATE, China: Unit 603, D Block, CAMIC International Convention Center, No 3, Hua Jia Di East road, ChaoYang district, Beijing 100102 P.R.
Need help?
Do you have a question about the UEL-1-150 and is the answer not in the manual?
Questions and answers