ADB Safegate UEL-1-150 User Manual

High intensity unidirectional elevated light for approach, threshold and runway end and for sequenced flashing lights (sfls), runway threshold identification (rtils) systems

Advertisement

High Intensity Unidirectional Elevated Light for Approach,
Threshold and Runway End and for Sequenced Flashing Lights
(SFLS)
Runway Threshold Identification (RTILS) Systems
User Manual
UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UEL-1-150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADB Safegate UEL-1-150

  • Page 1 High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Runway Threshold Identification (RTILS) Systems User Manual UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19...
  • Page 3 Material Handling Precautions and Storage precautions that must be followed. ADB SAFEGATE reserves the right to examine goods upon which a claim is made. Said goods must be presented in the same condition as when the defect therein was discovered. ADB SAFEGATE furthers reserves the right to require the return of such goods to establish any claim.
  • Page 4 This manual could contain technical inaccuracies or typographical errors. ADB SAFEGATE BV reserves the right to revise this manual from time to time in the contents thereof without obligation of ADB SAFEGATE BV to notify any person of such revision or change. Details and values given in this manual are average values and have been compiled with care. They are not binding, however, and ADB SAFEGATE BV disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers.
  • Page 5: Table Of Contents

    5.2.3 Illustration ........................................19 5.3 Electronic leveling device ....................................20 5.3.1 Introduction ......................................... 20 5.3.2 Composition ........................................ 20 5.3.3 Procedure ........................................20 5.3.4 Illustration ........................................21 5.4 Commissioning ........................................22 UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 6 8.3 Exploded views ........................................31 8.3.1 UEL-1-150 ........................................31 8.3.2 UEL-1-120 ........................................32 A.0 SUPPORT ....................................33 A.1 ADB SAFEGATE Website ...................................... 33 A.2 Recycling ............................................ 33 A.2.1 Local Authority Recycling ..................................33 A.2.2 ADB SAFEGATE Recycling ..................................34 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 7: Safety

    1.0 Safety Introduction to Safety This section contains general safety instructions for installing and using ADB SAFEGATE equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate.
  • Page 8: Introduction To Safety

    Using this equipment in ways other than described in this manual may result in personal injury, death or property and equipment damage. Use this equipment only as described in this manual. Failure to follow this instruction can result in serious injury or equipment damage Copyright ADB Safegate, All Rights Reserved ©...
  • Page 9: Material Handling Precautions: Storage

    Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component according to instructions provided in its manual. Failure to follow these instructions can result in death or equipment damage UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 10: Material Handling Precautions, Esd

    • Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks. • Only persons who are properly trained and familiar with ADB SAFEGATE equipment are permitted to service this equipment. • An open airfield current circuit is capable of generating >5000 Vac and may appear OFF to a meter.
  • Page 11: About This Manual

    2.0 About this Manual This manual describes the procedures for installation, maintenance and troubleshooting of the ADB SAFEGATE type UEL lights. This manual covers the light fixtures suitable for use in systems described in ICAO Annex 14, Attachment A, Section 11 .
  • Page 12 High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) About this Manual Copyright ADB Safegate, All Rights Reserved ©...
  • Page 13: Introduction

    3.2 Product data 3.2.1 Equipment supplied UEL units are either packed individually in a durable, cushioned and corrugated cardboard box, labeled with ADB SAFEGATE and ordering numbers, or on pallet boxes in larger quantities. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19...
  • Page 14: Uel Dimensions

    Velocities up to 560 km/hr Velocities up to 560 km/hr Weight Approx. 1.7 kg Approx. 2.0 kg 3.2.4 References Note For ordering codes and reference data pertinent to the product, see § Spare Parts Copyright ADB Safegate, All Rights Reserved ©...
  • Page 15: Installation

    4.2.2 Electrical connection • The UEL-1-150 light assemblies are designed for connection to 6.6 or 20 Amps series circuits via one FAA L-830 or L-831 isolation transformer (type ADB : RST), with a nominal secondary current of 6,6A. Refer to ADB cat. leaflet A.06.110 or Instruction manual AM.06.110 for more information on isolation transformers.
  • Page 16: Equipment Required For Installation

    The UEL is mounted on a breakable coupling which is screwed into a mounting device such as a conduit elbow or a deep base with cover. 4.4.2 Procedure 1. UEL-1-150 steady burning light Copyright ADB Safegate, All Rights Reserved ©...
  • Page 17 The following table instructs you on how to install the UEL-1-150 at ground level: a) Before installing the light, connect the plug of the two-core cable to the receptacle of the cable coming from the transformer. Note The transformer receptacle rests in the upper part of the conduit elbow or the cover plate.
  • Page 18: Illustration

    The UEL is mounted on a piece of aluminum conduit with 60 mm O.D, with a maximum length of 2 meters. The conduit is fastened in a breakable coupling, which in turn is screwed into a conduit elbow or on a base cover. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 19: Procedure

    1. UEL-1-150 steady burning light The following table instructs you on how to install the UEL-1-150 on a 60 mm O.D. conduit: a) Before installing the light, prepare a two-core cable with plug, making sure that a sufficient length of cable is available above the conduit elbow or cover plate.
  • Page 20: Illustration

    Once the position of the light is correct, put the optical cartridge back in place. h) Insert the lamp connector back in place. i) Close the light fitting. 4.5.3 Illustration The illustration below gives an overview of the procedure described above. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 21: How To Mount The Uel On A Safety Approach Mast

    When the UEL has to be installed at more than 2 meters (6.7 feet) above ground level, a safety approach mast with a 60 mm O.D. top piece must be used. 4.6.2 Procedure 1. UEL-1-150 steady burning light UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 22 High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Installation The following table instructs you on how to install the UEL-1-150 on a safety approach mast: a) Before installing the light, install a two-core secondary cable from the transformer to the top of the mast, according to the instructions of the manufacturer of the mast.
  • Page 23 Insert the lamp connector back in place. h) Close the light fitting. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 24 High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Installation Copyright ADB Safegate, All Rights Reserved ©...
  • Page 25: Orientation And Elevation Settings

    8. Remove the device. Put the optical cartridge back in place, without forgetting to connect the lamp. 5.2.3 Illustration The drawing below illustrates the procedure described above: UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 26: Electronic Leveling Device

    90° (down to the horizontal). With the mast in this position, adjust the light by turning it around the tube, and then tighten the bracing clamp. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 27: Illustration

    During the installation of the approach line, a quicker method is to use a platform at the light level for an easy initial adjustment. 5.3.4 Illustration The drawing below illustrates the procedure described above: UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 28: Commissioning

    A flight check shall be performed to detect gross misalignment in the approach and runway threshold lighting system. WARNING Errors shall be corrected and the system shall not be put in operation until it has been found satisfactory during the flight test. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 29: Maintenance

    Mark location of low mounted fixtures (use red flags or sticks) to facilitate snow removal and lessen the risk of damage to the fixtures by snow removal equipment. Notes More frequently during rainy seasons. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 30: How To Replace The Lamp

    1. Open the fitting by hinging down the optical cartridge (1). 2. (UEL-1-150): Slide the insulating sleeves away from the "fast-on" connectors and disconnect the lamp (2) from the cable wires.
  • Page 31: How To Dismantle The Optical Assembly

    3. Slide the front gasket (1a) around the front of the cartridge. This releases the reflector (1c) and the front glass (1b). 4. Reassembly is done in the opposite order. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 32: Illustration

    The clear front glass has a structure spreading the light, created by lines on the internal surface. Therefore, it is important that those lines be positioned vertically and not horizontally. 6.4.2 Illustration The illustrations below clarify the procedure described above. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 33: Troubleshooting

    Defective isolation transformer Check transformer secondary current (in short-circuit) with true RMS Ammeter. Short lamp life (UEL-1-150): Too high current (lamp will have black Check output current of isolating transformer at full burns) brightness. Current should not exceed 6.7 A.
  • Page 34 High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Troubleshooting Copyright ADB Safegate, All Rights Reserved ©...
  • Page 35: Assemblies And Exploded Views

    Other components that may need replacement, such as front glasses, hardware and sub-assemblies should be stocked in smaller quantities. The stock should also contain some optical cartridges and complete fittings of each type. 8.2.2 Ordering code UEL UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 36: Spare Parts And Numbers

    High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Assemblies and Exploded Views 8.2.3 Spare Parts and numbers In the table below you will find all parts of the UEL-1-150 and UEL-1-120 lights. References related to exploded view UEL White...
  • Page 37: Exploded Views

    8.3 Exploded views 8.3.1 UEL-1-150 The illustration below shows the exploded view of the UEL-1-150. UM-4020 / AM02-630e, Rev. 2.0, 2020/05/19 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 38: Uel-1-120

    High Intensity Unidirectional Elevated Light for Approach, Threshold and Runway End and for Sequenced Flashing Lights (SFLS) Assemblies and Exploded Views 8.3.2 UEL-1-120 The illustration below shows the exploded views of the UEL–1-120. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 39: Support

    A.2.1 Local Authority Recycling The disposal of ADB SAFEGATE products is to be made at an applicable collection point for the recycling of electrical and electronic equipment. The correct disposal of equipment prevents any potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling.
  • Page 40: Adb Safegate Recycling

    Main Unit Serial Number. ADB SAFEGATE will continue to monitor and update according for any future requirements for EU directives as and when EU member states implement new regulations and or amendments. It is our aim to maintain our compliance plan and assist our customers.
  • Page 41 Tel.: +46 (0)40 699 17 00, Internet: www.adbsafegate.com Fax: +46 (0)40 699 17 30 ADB SAFEGATE Airfield Technologies Ltd. China ADB SAFEGATE, China: Unit 603, D Block, CAMIC International Convention Center, No 3, Hua Jia Di East road, ChaoYang district, Beijing 100102 P.R.

This manual is also suitable for:

Uel-1-120