IEI Technology HTB-150-N6210 User Manual

IEI Technology HTB-150-N6210 User Manual

Medical embedded system with intel celeron n6210 cpu, lpddr4x, 32 gb emmc, rs-232, dual gbe lan, usb 3.2 gen 2, m.2, hdmi and rohs
Table of Contents

Advertisement

Quick Links

HTB-150-N6210 Medical Embedded System
HTB-150-N6210 Box PC
MODEL:
MODEL:
HTB-150-N6210
Medical Embedded System with Intel
®
Celeron® N6210 CPU,
LPDDR4x, 32 GB eMMC, RS-232, Dual GbE LAN,
USB 3.2 Gen 2, M.2, HDMI and RoHS
User Manual
Page i
Rev. 1.00 – September 25, 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HTB-150-N6210 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IEI Technology HTB-150-N6210

  • Page 1 HTB-150-N6210 Medical Embedded System HTB-150-N6210 Box PC MODEL: MODEL: HTB-150-N6210 Medical Embedded System with Intel ® Celeron® N6210 CPU, LPDDR4x, 32 GB eMMC, RS-232, Dual GbE LAN, USB 3.2 Gen 2, M.2, HDMI and RoHS User Manual Page i Rev. 1.00 – September 25, 2023...
  • Page 2 HTB-150-N6210 Medical Embedded System Revision Date Version Changes September 25, 2023 1.00 Initial release Page ii...
  • Page 3 HTB-150-N6210 Medical Embedded System Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
  • Page 4 HTB-150-N6210 Medical Embedded System Manual Conventions WARNING Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product.
  • Page 5: Table Of Contents

    HTB-150-N6210 Medical Embedded System Table of Contents 1 INTRODUCTION ......................1 1.1 O ........................2 VERVIEW 1.2 F ........................2 EATURES 1.3 F ......................3 RONT ANEL 1.4 R ......................3 ANEL 1.5 B ......................4 OTTOM ANEL 1.6 T ..................
  • Page 6 HTB-150-N6210 Medical Embedded System 4 BIOS ..........................25 4.1 I ......................26 NTRODUCTION 4.1.1 Starting Setup ....................26 4.1.2 Using Setup ...................... 27 4.1.2.1 Keyboard Navigation ................27 4.1.2.2 Touch Navigation ..................28 4.1.3 Getting Help ..................... 28 4.1.4 Unable to Reboot after Configuration Changes ..........29 4.1.5 BIOS Menu Bar ....................
  • Page 7 HTB-150-N6210 Medical Embedded System C MAINTENANCE AND CLEANING PRECAUTIONS .......... 62 C.1.1 Maintenance and Cleaning ................64 C.1.2 Cleaning Tools ....................64 D SYMBOL DEFINITIONS ..................65 E WATCHDOG TIMER ....................67 F ERROR BEEP CODE ....................70 F.1 PEI B ......................
  • Page 8 HTB-150-N6210 Medical Embedded System List of Figures Figure 1-1: HTB-150-N6210 Medical Embedded System ............2 Figure 1-2: Front Panel ........................3 Figure 1-3: Rear Panel ........................3 Figure 1-4: Bottom Panel ....................... 4 Figure 1-5: Dimensions (mm) ......................7 Figure 3-1: Ethernet Connector ....................16 Figure 3-2: AT/ATX Switch Location ...................
  • Page 9 HTB-150-N6210 Medical Embedded System List of Tables Table 1-1: Technical Specifications ....................6 Table 2-1: Package List ........................ 10 Table 3-1: Ethernet Connector Pinouts ..................15 Table 3-2: Connector LEDs ......................16 Table 3-3: RS-232 Serial Port Pinouts ..................16 Table 4-1: BIOS Navigation Keys ....................
  • Page 10 HTB-150-N6210 Medical Embedded System List of BIOS Menus BIOS Menu 1: Main ........................30 BIOS Menu 2: Advanced ......................31 BIOS Menu 3: CPU Configuration ....................32 BIOS Menu 4: Trusted Computing ....................34 BIOS Menu 5: IT5571 Super IO Configuration ................35 BIOS Menu 6: Serial Port 1 Configuration Menu ...............
  • Page 11: Introduction

    HTB-150-N6210 Medical Embedded System Chapter Introduction Page 1...
  • Page 12: Overview

    Wi-Fi 6E module to provide wireless communication. The HTB-150-N6210 is built-in with 32GB eMMC for storage, and it is capable of supporting one M.2 PCIe SSD module via 2280 M-key slot. 1.2 Features The HTB-150-N6210 has the following features ...
  • Page 13: Front Panel

    Figure 1-2: Front Panel 1.4 Rear Panel The rear panel of the HTB-150-N6210 provides access to the following external I/O 6 9 2 H 6 9 2 H 5 6 9 H connectors, button and switches as shown in Figure 1-3.
  • Page 14: Bottom Panel

    HTB-150-N6210 Medical Embedded System 1.5 Bottom Panel The bottom panel has four screw holes for VESA 75 mounting. Figure 1-4: Bottom Panel Page 4...
  • Page 15: Technical Specifications

    HTB-150-N6210 Medical Embedded System 1.6 Technical Specifications The specifications for the Intel based medical embedded systems are listed below. HTB-150-N6210 Intel® Celeron® Processor N6210 2 x Intel® I225-V Ethernet controllers On-board 8GB LPDDR4x System Memory On-board 32GB eMMC Storage Expansion 1 x M.2 2230 A key slot (PCIe + USB)
  • Page 16: Table 1-1: Technical Specifications

    HTB-150-N6210 Medical Embedded System Power Adapter 65 W FSP FSP065M-DHA medical-grade power adapter (P/N: 63040-010065-500-RS) Input: 100 V AC - 240 V AC, 50 Hz - 60 Hz, 2.0 A – 1.0 A Output: 12 V 5.42 A 5G peak acceleration (11ms duration)
  • Page 17: Dimensions

    HTB-150-N6210 Medical Embedded System 1.7 Dimensions The dimensions of the HTB-150-N6210 are shown in F igure 1-5. 6 8 8 H 6 8 8 H 5 6 7 H Figure 1-5: Dimensions (mm) Page 7...
  • Page 18: Unpacking

    HTB-150-N6210 Medical Embedded System Chapter Unpacking Page 8...
  • Page 19: Unpacking

    Contact the IEI reseller or vendor the HTB-150-N6210 was purchased from or contact an IEI sales representative directly by sending an email to ales@ieiworld.com. 3 2 6 H 3 7 8 H The HTB-150-N6210 medical embedded system is shipped with the following components: Page 9...
  • Page 20: Table 2-1: Package List

    HTB-150-N6210 Medical Embedded System Quantity Item Image HTB-150-N6210 medical embedded system Power cord Medical grade power adapter 63040-010065-500-RS (FSP FSP065M-DHA, 65W) Mounting brackets Mounting bracket retention screws (M3*6) VESA mount screws (M4*8) Table 2-1: Package List Page 10...
  • Page 21: Installation

    HTB-150-N6210 Medical Embedded System Chapter Installation Page 11...
  • Page 22: Safety Precautions

     Electric shocks can occur if the HTB-150-N6210 chassis is opened when the HTB-150-N6210 is running. To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Page 12...
  • Page 23: Anti-Static Precautions

    Never replace or repair any components on your own. If the components  of the HTB-150-N6210 fails or malfunctions it must be shipped back to IEI to be repaired. Please contact the system vendor, reseller or an IEI sales person directly.
  • Page 24 During the time the board is handled, frequently touch any conducting materials that are connected to the ground. Use an anti-static pad: When configuring the HTB-150-N6210, place it on an  anti-static pad. This reduces the possibility of ESD damaging the HTB-150-N6210.
  • Page 25: Installation Precautions

    HTB-150-N6210 Medical Embedded System 3.3 Installation Precautions When installing the medical embedded system, please follow the precautions listed below:  Certified Engineers: Only certified engineers should install and modify the hardware settings.  Power turned off: When installing the medical embedded system, make sure the power is off.
  • Page 26: Rs-232 Serial Device Connection

    100 Mb/s orange: 1000 Mb/s Table 3-2: Connector LEDs 3.5 RS-232 Serial Device Connection The HTB-150-N6210 series has one RS-232 port (COM1) on the rear panel. The pinouts of the serial port are listed below. Description Description Table 3-3: RS-232 Serial Port Pinouts...
  • Page 27: At/Atx Mode Selection

    HTB-150-N6210 Medical Embedded System 3.6 AT/ATX Mode Selection AT or ATX power mode can be used on the HTB-150-N6210. The selection is made through an AT/ATX switch located on the bottom panel (Figure 3-2). Figure 3-2: AT/ATX Switch Location 3.7 Mounting the System 3.7.1 Using Mounting Brackets...
  • Page 28: Figure 3-4: Mounting Dimensions

    HTB-150-N6210 Medical Embedded System Figure 3-4: Mounting Dimensions Step 5: Insert four retention screws, two in each bracket, to secure the system to the wall. Step 0: Page 18...
  • Page 29: Vesa Mounting

    HTB-150-N6210 Medical Embedded System 3.7.2 VESA Mounting The HTB-150-N6210 is VESA (4 screws: M4 type, 8 mm length) compliant and can be mounted on a mounting device with a 75 mm interface pad. The HTB-150-N6210 VESA mount retention screw holes are shown below. Refer to the installation guide that came with the mounting device to mount the HTB-150-N6210.
  • Page 30: Power-On Procedure

    Ensure to connect the power cord to a socket-outlet with earthing connection. NOTE: The FSP FSP065M-DHA power adapter came with the HTB-150-N6210 is a forming part of the medical device. Step 2: Connect the power adapter to the power connector of the HTB-150-N6210. The power LED lights on in amber, indicating the system is ready to power on.
  • Page 31: Clear Cmos

    HTB-150-N6210 Medical Embedded System 3.9 Clear CMOS If the HTB-150-N6210 fails to boot due to improper BIOS settings, use the clear CMOS button clears the CMOS data and resets the system BIOS information. To do this, push the button for three seconds and restart the system. The clear CMOS button location is shown in F igure 3-7.
  • Page 32: Available Drivers

    HTB-150-N6210 Medical Embedded System 3.11 Available Drivers All the drivers for the HTB-150-N6210 are available on IEI Resource Download Center (https://download.ieiworld.com). Type HTB-150-N6210 and press Enter to find all the relevant software, utilities, and documentation. Figure 3-9: IEI Resource Download Center 3.11.1 Driver Download...
  • Page 33 HTB-150-N6210 Medical Embedded System Step 3: Click the driver file name on the page and you will be prompted with the  following window. You can download the entire ISO file ( ), or click the small  arrow to find an individual driver and click the file name to download (...
  • Page 34: System Maintenance

    HTB-150-N6210 Medical Embedded System 3.12 System Maintenance If the components of the HTB-150-N6210 fail, they must be replaced. Please contact the system reseller or vendor to purchase the replacement parts. NOTE: A user cannot replace a motherboard. If the motherboard fails it must be shipped back to IEI to be replaced.
  • Page 35: Bios

    HTB-150-N6210 Medical Embedded System Chapter BIOS Page 25...
  • Page 36: Introduction

    HTB-150-N6210 Medical Embedded System 4.1 Introduction A licensed copy of the BIOS is preprogrammed into the ROM BIOS. The BIOS setup program allows users to modify the basic system configuration. This chapter describes how to access the BIOS setup program and the configuration options that may be changed.
  • Page 37: Using Setup

    HTB-150-N6210 Medical Embedded System 4.1.2 Using Setup The BIOS Setup menu can be navigated by using a keyboard or a touchscreen. 4.1.2.1 Keyboard Navigation For keyboard navigation, use the navigation keys shown in Table 4-1. Function Up arrow Move to previous item...
  • Page 38: Touch Navigation

    HTB-150-N6210 Medical Embedded System 4.1.2.2 Touch Navigation For touchscreen navigation, use the on-screen navigation keys shown below. On-screen Button Function Previous Values Load the last value you set. Optimized Defaults Load the factory default values in order to achieve the best performance.
  • Page 39: Unable To Reboot After Configuration Changes

    HTB-150-N6210 Medical Embedded System 4.1.4 Unable to Reboot after Configuration Changes If the computer cannot boot after changes to the system configuration are made, CMOS defaults. 4.1.5 BIOS Menu Bar The menu bar on top of the BIOS screen has the following main items: ...
  • Page 40: Main

    HTB-150-N6210 Medical Embedded System 4.2 Main The Main BIOS menu ( B IOS Menu 1) appears when the BIOS Setup program is entered. 8 6 4 H 8 3 5 H The Main menu gives an overview of the basic system information.
  • Page 41: Advanced

    HTB-150-N6210 Medical Embedded System 4.3 Advanced Use the Advanced menu ( B IOS Menu 2) to configure the CPU and peripheral devices 8 6 5 H 8 3 6 H through the following sub-menus: BIOS Menu 2: Advanced Page 31...
  • Page 42: Cpu Configuration

    HTB-150-N6210 Medical Embedded System 4.3.1 CPU Configuration Use the CPU Configuration ( B IOS Menu 3) to view detailed CPU specifications and 8 3 9 H configure the CPU. BIOS Menu 3: CPU Configuration  Intel(R) SpeedStep(tm) [Enabled] Use the Intel(R) SpeedStep(tm) option to enable or disable the Intel® SpeedStep™...
  • Page 43 HTB-150-N6210 Medical Embedded System  Disabled EFAULT Disables CPU power management  Enabled Enables CPU power management  Intel Virtualization Technology [Enabled] Use the Intel Virtualization Technology option to enable or disable virtualization on the system. When combined with third party software, Intel® Virtualization technology allows several OSs to run on the same system at the same time.
  • Page 44: Trusted Computing

    HTB-150-N6210 Medical Embedded System 12.50W, enter 12500. Processor applies control policies such that the package power does not exceed this limit. 4.3.2 Trusted Computing Use the Trusted Computing menu (BIOS Menu 4) to configure settings related to the Trusted Computing Group (TCG) Trusted Platform Module (TPM).
  • Page 45: It5571 Super Io Configuration

    HTB-150-N6210 Medical Embedded System  Pending Operation [None] Use the Pending Operation option to schedule an operation for the security device.  None TPM information is previous EFAULT  TPM information is cleared TPM Clear 4.3.3 IT5571 Super IO Configuration Use the IT5571 Super IO Configuration menu (BIOS Menu 5) to set or change the configurations for the serial ports and parallel port.
  • Page 46: Serial Port 1 Configuration

    HTB-150-N6210 Medical Embedded System 4.3.3.1 Serial Port 1 Configuration Use the Serial Port 1 Configuration menu (BIOS Menu 6) to configure the serial port 1. BIOS Menu 6: Serial Port 1 Configuration Menu  Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port.
  • Page 47: Serial Port 2 Configuration

    HTB-150-N6210 Medical Embedded System 4.3.3.2 Serial Port 2 Configuration Use the Serial Port 2 Configuration menu (BIOS Menu 7) to configure the serial port 2. BIOS Menu 7: Serial Port 2 Configuration Menu  Serial Port [Enabled] Use the Serial Port option to enable or disable the serial port.
  • Page 48: It5571 H/W Monitor

    HTB-150-N6210 Medical Embedded System 4.3.4 IT5571 H/W Monitor The IT5571 H/W Monitor menu ( B IOS Menu 8) shows the state of H/W real-time 8 4 5 H operating temperature, fan speeds and system voltages. BIOS Menu 8: IT5571 H/W Monitor ...
  • Page 49: Rtc Wake Settings

    HTB-150-N6210 Medical Embedded System +3.3V +3.3VSB 4.3.5 RTC Wake Settings The RTC Wake Settings menu ( B IOS Menu 9) configures RTC wake event. 8 3 8 H BIOS Menu 9: RTC Wake Settings  Wake System with Fixed Time [Disabled] Use the Wake System with Fixed Time option to specify the time the system should be roused from a suspended state.
  • Page 50: Serial Port Console Redirection

    HTB-150-N6210 Medical Embedded System  If selected, the following appears with values that Enabled can be selected: *Wake up every day *Wake up date *Wake up hour *Wake up minute *Wake up second After setting the alarm, the computer turns itself on from a suspend state when the alarm goes off.
  • Page 51: Network Stack Configuration

    HTB-150-N6210 Medical Embedded System  Console Redirection [Disabled] Use Console Redirection option to enable or disable the console redirection function.  Disabled the console redirection function Disabled EFAULT  Enabled Enabled the console redirection function 4.3.7 Network Stack Configuration The Network Stack Configuration menu (...
  • Page 52: Nvme Configuration

    HTB-150-N6210 Medical Embedded System 4.3.8 NVMe Configuration Use the NVMe Configuration (BIOS Menu 12) menu to display the NVMe controller and device information. BIOS Menu 12: NVMe Configuration Page 42...
  • Page 53: Chipset

    HTB-150-N6210 Medical Embedded System 4.4 Chipset Use the Chipset menu (BIOS Menu 13) to configure the system chipset. BIOS Menu 13: Chipset Page 43...
  • Page 54: System Agent (Sa) Configuration

    HTB-150-N6210 Medical Embedded System 4.4.1 System Agent (SA) Configuration Use the System Agent (SA) Configuration menu (BIOS Menu 14) to configure the System Agent (SA) parameters. BIOS Menu 14: System Agent (SA) Configuration  VT-d [Enabled] Use the VT-d option to enable or disable VT-d support.
  • Page 55: Memory Configuration

    HTB-150-N6210 Medical Embedded System 4.4.1.1 Memory Configuration Use the Memory Configuration submenu ( B IOS Menu 15) to display the memory 6 3 2 H information. BIOS Menu 15: Memory Configuration Page 45...
  • Page 56: Graphics Configuration

    HTB-150-N6210 Medical Embedded System 4.4.1.2 Graphics Configuration Use the Graphics Configuration menu ( B IOS Menu 16) to view the graphics settings. 6 3 2 H BIOS Menu 16: Graphics Configuration Page 46...
  • Page 57: Pch-Io Configuration

    HTB-150-N6210 Medical Embedded System 4.4.2 PCH-IO Configuration Use the PCH-IO Configuration menu (BIOS Menu 17) to configure the PCH-IO chipset. BIOS Menu 17: PCH-IO Configuration  Restore AC Power Loss [Last State] Use the Restore AC Power BIOS option to specify what state the system returns to if there is a sudden loss of power to the system.
  • Page 58 HTB-150-N6210 Medical Embedded System  Power Saving Function(ERP) [Disabled] Use the Power Saving Function(ERP) BIOS option to enable or disable the power saving function.  Disabled Power saving function is disabled. EFAULT  Enabled Power saving function is enabled. It will reduce power consumption when the system is off.
  • Page 59: Pci Express Configuration

    HTB-150-N6210 Medical Embedded System 4.4.2.1 PCI Express Configuration Use the PCI Express Configuration submenu (BIOS Menu 18) to configure the PCI Express slots. BIOS Menu 18: PCI Express Configuration  M2_A1 / M2_M1 [Enabled] Use the M2_A1 / M2_M1 option to enable or disable the M.2 expansion slot.
  • Page 60: Sata Configuration

    HTB-150-N6210 Medical Embedded System  Gen 2  Gen 3  Detect Non-Compliance Device [Disabled] Use the Detect Non-Compliance Device option to enable or disable detecting if a non-compliance PCI Express device is connected to the PCI Express slot. ...
  • Page 61: Hd Audio Configuration

    HTB-150-N6210 Medical Embedded System  SATA Mode Selection [AHCI] Use the SATA Mode Selection option to configure how the SATA controller(s) operate.  AHCI EFAULT Configures SATA devices as AHCI device. 4.4.2.3 HD Audio Configuration Use the HD Audio Configuration menu (BIOS Menu 20) to configure the PCH Azalia settings.
  • Page 62: Security

    HTB-150-N6210 Medical Embedded System 4.5 Security Use the Security menu (BIOS Menu 21) to set system and user passwords. BIOS Menu 21: Security  Administrator Password Use the Administrator Password field to set or change an administrator password.  User Password Use the User Password field to set or change a user password.
  • Page 63: Boot

    HTB-150-N6210 Medical Embedded System 4.6 Boot Use the Boot menu ( B IOS Menu 22) to configure system boot options. 8 5 2 H BIOS Menu 22: Boot  Quiet Boot [Enabled] Use the Quiet Boot BIOS option to select the screen display when the system boots.
  • Page 64: Bios Menu 23: Save & Exit

    HTB-150-N6210 Medical Embedded System BIOS Menu 23: Save & Exit  Save Changes and Reset Use the Save Changes and Reset option to save the changes made to the BIOS options and reset the system.  Discard Changes and Reset Use the Discard Changes and Reset option to exit the system without saving the changes made to the BIOS configuration setup program.
  • Page 65: A Regulatory Compliance

    HTB-150-N6210 Medical Embedded System Appendix Regulatory Compliance Page 55...
  • Page 66 HTB-150-N6210 Medical Embedded System DECLARATION OF CONFORMITY This equipment is in conformity with the following EU directives: EMC Directive (2004/108/EC, 2014/30/EU)  Low-Voltage Directive (2006/95/EC, 2014/35/EU)  RoHS II Directive (2011/65/EU, 2015/863/EU)  Medical Device Directive 93/42/EEC: EN 60601-1 ...
  • Page 67 HTB-150-N6210 Medical Embedded System Italiano [Italian] IEI Integration Corp. dichiara che questo apparecchio è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014/53/EU. Latviski [Latvian] IEI Integration Corp. deklarē, ka iekārta atbilst būtiskajām prasībām un citiem ar to saistītajiem noteikumiem Direktīvas 2014/53/EU.
  • Page 68 HTB-150-N6210 Medical Embedded System FCC WARNING This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and  This device must accept any interference received, including interference ...
  • Page 69 HTB-150-N6210 Medical Embedded System UL CLASSIFIED The label on the product indicates this product complies with the requirements of ANSI/AAMI ES60601-1:2005/(R)2012 A1:2012/(R)2012 A2:2021; CAN/CSA-C22.2 No. 60601-1 (Amendment 2:2022 (MOD) to CAN/CSA-C22.2 No. 60601-1:14). ROHS STATEMENT The label on the product indicates this product conforms to European (EU) Restriction of Hazardous Substances (RoHS) that set maximum concentration limits on hazardous materials used in electrical and electronic equipment.
  • Page 70: B Product Disposal

    HTB-150-N6210 Medical Embedded System Appendix Product Disposal Page 60...
  • Page 71 HTB-150-N6210 Medical Embedded System CAUTION / ATTENTION Risk of explosion if battery is replaced by an incorrect type. Only certified engineers should replace the on-board battery. Risque d'explosion si la batterie est remplacée par un type incorrect. Seuls les ingénieurs certifiés doivent remplacer la batterie embarquée.
  • Page 72: C Maintenance And Cleaning Precautions

    HTB-150-N6210 Medical Embedded System Appendix Maintenance and Cleaning Precautions Page 62...
  • Page 73 HTB-150-N6210 Medical Embedded System When maintaining or cleaning the HTB-150-N6210, please follow the guidelines below. WARNING / AVERTISSEMENT If you dropped any material or liquid such as water onto the embedded system when cleaning, unplug the power cable immediately and contact your dealer or the nearest service center.
  • Page 74: Maintenance And Cleaning

    Some components in the HTB-150-N6210 may only be cleaned using a product specifically designed for the purpose. In such case, the product will be explicitly mentioned in the cleaning tips. Below is a list of items to use when cleaning the HTB-150-N6210. ...
  • Page 75: D Symbol Definitions

    HTB-150-N6210 Medical Embedded System Appendix Symbol Definitions Page 65...
  • Page 76 HTB-150-N6210 Medical Embedded System The following symbols appear on the product, its labeling, or the product packing. Each symbol carries a special definition, as defined below: Direct current Fragile, handle with care AC current Keep dry Protective earth (ground) This side up...
  • Page 77: E Watchdog Timer

    HTB-150-N6210 Medical Embedded System Appendix Watchdog Timer Page 67...
  • Page 78 HTB-150-N6210 Medical Embedded System NOTE: The following discussion applies to DOS. Contact IEI support or visit the IEI website for drivers for other operating systems. The Watchdog Timer is a hardware-based timer that attempts to restart the system when it stops working.
  • Page 79 HTB-150-N6210 Medical Embedded System NOTE: The Watchdog Timer is activated through software. The software application that activates the Watchdog Timer must also deactivate it when closed. If the Watchdog Timer is not deactivated, the system will automatically restart after the Timer has finished its countdown.
  • Page 80: F Error Beep Code

    HTB-150-N6210 Medical Embedded System Appendix Error Beep Code Page 70...
  • Page 81: Pei Beep Codes

    HTB-150-N6210 Medical Embedded System F.1 PEI Beep Codes Number of Beeps Description Memory not Installed Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed...
  • Page 82: G Hazardous Materials Disclosure

    HTB-150-N6210 Medical Embedded System Appendix Hazardous Materials Disclosure Page 72...
  • Page 83: Rohs Ii Directive (2015/863/Eu)

    HTB-150-N6210 Medical Embedded System G.1 RoHS II Directive (2015/863/EU) The details provided in this appendix are to ensure that the product is compliant with the RoHS II Directive (2015/863/EU). The table below acknowledges the presences of small quantities of certain substances in the product, and is applicable to RoHS II Directive (2015/863/EU).
  • Page 84: China Rohs

    HTB-150-N6210 Medical Embedded System G.2 China RoHS 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符 合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的 年限。本产品可能包含有较短的环境友好使用期限的可替换元件,像是电池或灯管,这些 元件将会单独标示出来。 部件名称 有毒有害物质或元素 壳体 显示 印刷电路板 金属螺帽 电缆组装 风扇组装 电力供应组装 电池 O: 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ/T11364-2014 與 GB/T26572-2011 标准规定的限量要求以下。 X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T11364-2014 與 GB/T26572-2011 标准规定的限量要求。 Page 74...

Table of Contents