Setting/Acquiring the Measurement Conditions < MEASPARA command >

Setting measurement conditions

This command sets the detailed conditions and thresholds of specified items.
< Command format >
M E A S
P A R A
< Response format >
When processing ends successfully
C R
O K
When processing fails
E R
C R
< Explanation of parameters >
Measurement item No.
Specifies the measurement item No. (0 to 127)
Data No.
Specifies the data No. (0 to 127)
Setting value
Specifies the setting value.
Acquiring measurement conditions
This command acquires the detailed conditions and thresholds of specified items.
< Command format >
M E A S P A R A
< Response format >
When processing ends successfully
Acquired value
C R
C R
O K
When processing fails
C R
E R
ZFX-C Serial Communication Command Reference
or
Setting value
C R
M P
Data No.
(max. 3 digits)
Measurement
item No.
(max. 3 digits)
"Parameter List (p.39)."
For details, see
"Parameter List (p.39)."