Omron ZFX-C Command Reference Manual page 46

Smart sensor
Hide thumbs Also See for ZFX-C:
Table of Contents

Advertisement

Brightness and color inspection parameters
Brightness
Data No.
0
1
2
3
4
5
6
Hue
Data No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
44
About Communication Commands
Parameter
Judgment result
Density average
Density deviation
Reference density average
Reference density deviation
Density average difference
Density deviation difference
Parameter
Judgment result
Hue
Saturation
Value
Hue deviation
Saturation deviation
Value deviation
Reference hue
Reference saturation
Reference value
Hue difference
Saturation difference
Value difference
Reference hue deviation
Reference saturation deviation
Reference value deviation
Hue deviation difference
Saturation deviation difference
Value deviation difference
Maximum hue
Minimum hue
Maximum saturation
Minimum saturation
Output Range
0: OK
-1: NG
-2: not measured
0 to 255.0
0 to 127.0
0 to 255.0
0 to 127.0
0 to 255.0
0 to 127.0
Output Range
0: OK
-1: NG
-2: not measured
0 to 360.0
0 to 100.0
0 to 100.0
0 to 180.0
0 to 50.0
0 to 50.0
0 to 360.0
0 to 100.0
0 to 100.0
-360.0 to 360.0
-100.0 to 100.0
-100.0 to 100.0
0 to 180.0
0 to 50.0
0 to 50.0
-180.0 to 180.0
-50.0 to 50.0
-50.0 to 50.0
0 to 360.0
0 to 360.0
0 to 100.0
0 to 100.0