Omron Z5FP-MC10 Setup Manual page 60

Multi-dimensional sensor
Table of Contents

Advertisement

SECTION 4
Appendix
JIS C6802 "Radiation Safety Standards for Laser Products"
Requirements;
Sub-clause
Description of
hazard class
Protective housing
Safety interlock in
protective housing
Remote control
Key control
Emission warning
device
Attenuator
Location controls
Viewing optics
Scanning
Class label
Aperture label
Service entry label
Override interlock
label
User information
Purchasing and
service informa-
tion
Additional
requirements for
laser optical fibre
transmission sys-
tem
With respect to the requirements of remote interlock connector, key control, emission warning and attenuator, Class
3B laser products not exceeding five times the AEL of Class 2 in the wavelength range of 400 to 700 nm are to be
treated as Class 3A laser products.
Note: This table is intended to provide a convenient summary of requirements. See text of standard for complete
requirements.
58
Setup Manual
Class 1
Class 2
Low power; eye
Safe inherently
protection nor-
by engineering
mally afforded by
design
aversion
responses
Required for each laser product; limits access necessary for performance of functions of the
products
Designed to prevent removal of the panel until accessible emission values are below the AEL
for the class assigned
Not required
Not required
Not required
Not required
Not required
Emission from all viewing systems must be below Class 1 AEL's as applicable
Scan failure shall not cause product to exceed its classification
Required word-
Warning and explanatory labels and specified wording (Refer to page 6)
ing
Not required
Required as appropriate to the class of accessible radiation
Required under certain conditions as appropriate to the class of laser used
Operation manuals must contain instructions for safe use
Promotion brochures must reproduce classification labels; service manuals must contain
safety information
Cable service connections require tool to disconnect if disconnection breaks protective hous-
ing and permits access above Class 1
Classification
Class 3A
Class 3B
Same as Class
2. Direct intra-
Direct intrabeam
beam viewing
viewing may be
with optical aids
hazardous
may be hazard-
ous
Permits easy addition of external
interlock in laser installation
Laser inoperative when key is
removed
Give audible or visible warning
when laser is switched on or if
capacitor bank of pulsed laser is
being charged
Give means beside On/Off switch to
temporarily block beam
Controls located so adjustment does not require expo-
sure to AEL above class 1 or 2
Specified wording required
Class 4
High power; dif-
fused reflection
may be hazard-
ous

Advertisement