SECTION 4
Appendix
General specifications
Materials
Weight
Performance specifications
Number of
connectable sensors
Number of scenes
Averaging number
Sensor control
Area specification
function
Control of quantity of
light
Measurement time *2
Run Mode
Image preprocessing
Measurement pre-
processing
Detection method
Measurement item
Logging function
Output pre-processing Forced zero, Offset/span adjustment
Profile data output
Results output
Screen Displays
Tool function
Terminal blocks
RS-232C
(Baud rate)
Monitor interface
Analog output
resolution
*1 Average current at normal operation after power is ON.
*2 The sampling interval varies depending on the measurement settings. Check the actual sampling interval
on the image monitor.
*3 When performing measurement taking the average of every 64 measurements with an OMRON K3AS
linear sensor controller connected.
48
Setup Manual
Console: ABS
Approx. 0.7kg
Up to two Z550-SW70 sensors can be connected.
16
9 levels (1 to 256 times)
6 levels (varies depending on the sensor)
Available
Multi-sensitivity adjustment (dynamic range or sampling interval takes precedence)
fixed sensitivity, automatic sensitivity adjustment
100 ms (at fixed sensitivity)
120 ms (at automatic sensitivity)
100 ms to 250 ms (when sampling interval takes precedence)
100 ms to 629 ms (when dynamic range takes precedence)
Continuous measurement or trigger measurement
Noise removal
Interpolation processing, filter processing
Inclination compensation processing
Height and position compensation processing
Height position method
Reflectance method
Height, Step: 2 pts, Step: 3 pts, Edge position, Width, Edge center, Peak/Bottom,
Cross-sectional area, Inclination, Roughness, User-defined
The measurement results of up to 3000 measurements can be stored. (It is possible
to select after how many measurements their measurement results are stored.)
Up to 1024 height profiles can be output in one batch.
The output format may be either ASCII code or binary format (when sending via
XMODEM)
Terminal block: Judgment result
Analog: Measurement result
RS-232C: Measurement result, judgment result, profile data
Image monitor, Trend monitor, Digital monitor, Profile monitor
Peripheral image display function, test measurement function
11 input points:TRIGGER, LD-OFF, RESET, DI0 to DI7
21 output points: DO0 to DO19 and GATE
Up to 115 kbps (at XMODEM transmission, external trigger measurement)
Normally 38.4 kbps
1 channel (for pin jack or overscan monitor)
The full output scale can be divided into a maximum of 40,000 divisions.
Resolution (*3): 0.25 mV (± 5 V), 0.4 µA (4 to 20 µA)