Specifications - Omron G7J Datasheet

Power relay
Table of Contents

Advertisement

Specifications

■ Coil Ratings
Rated voltage
Rated current
AC
24 VAC
75 mA
50 VAC
36 mA
100 to 120 VAC
18 to 21.6 mA
200 to 240 VAC
9 to 10.8 mA
DC
6 VDC
333 mA
12 VDC
167 mA
24 VDC
83 mA
48 VDC
42 mA
100 VDC
20 mA
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of +15%/–20% for AC rated current and
15% for DC coil resistance. (The values given for AC rated current apply at 50 Hz or 60 Hz.)
2. Performance characteristic data are measured at a coil temperature of 23 C.
3. The maximum voltage is one that is applicable to the Relay coil at 23 C.
■ Contact Ratings
Item
Contact mechanism
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Note: The values in parentheses indicate values for a bifurcated contact.
■ Characteristics
Contact resistance (see note 2)
Operate time (see note 3)
Release time (see note 3)
Max. operating frequency
Insulation resistance (see note 4)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Error rate (see note 6)
Ambient temperature
Ambient humidity
Weight
Coil resistance
Must-operate
voltage
---
75% max. of rated
voltage
---
---
---
18
72
288
1,150
5,000
Resistive load (cos
= 1)
Double break
Ag alloy
NO: 25 A at 220 VAC (24 A at 230 VAC)
NC: 8 A at 220 VAC (7.5 A at 230 VAC)
NO: 25 A (1 A)
NC: 8 A (1 A)
250 VAC
NO: 25 A (1 A)
NC: 8 A (1 A)
50 m max.
50 ms max.
50 ms max.
Mechanical: 1,800 operations/hr
Electrical:
1,800 operations/hr
1,000 M min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
4,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
10,000 V between coil and contact (with 1.2 x 50 s impulse wave)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: NO:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
NC:10 to 26 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
2
Destruction: 1,000 m/s
2
Malfunction: NO:100 m/s
2
NC:20 m/s
Mechanical: 1,000,000 operations min. (at 1,800 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr) (see note 5)
100 mA at 24 VDC (bifurcated contact: 24 VDC 10 mA)
Operating: –25 C to 60 C (with no icing or condensation)
Operating: 5% to 85%
PCB terminal:
approx. 140 g
Screw terminal:
approx. 165 g
Quick-connect terminal: approx. 140 g
Must-release
Max. voltage
voltage
15% min. of rated
110% of rated
voltage
voltage
10% min. of rated
voltage
Inductive load (cos = 0.4)
NO: 25 A at 30 VDC
NC: 8 A at 30 VDC
125 VDC
Power Relay
Power
consumption
Approx. 1.8 to
2.6 VA
Approx. 2.0 W
Resistive load
G7J
A-59

Advertisement