Connections; References On The Terminal Board - Omron F3SP-U5P-TGR User Manual

F3sp-u5p-tgr series single beam safety control unit safety level 4
Hide thumbs Also See for F3SP-U5P-TGR:
Table of Contents

Advertisement

F3SP-U5P-TGR
Do not install the safety PES in a location affected by shiny surface
reflections.
5

CONNECTIONS.

5.1

REFERENCES ON THE TERMINAL BOARD.

TERMINAL BLOCK ASSIGNMENT
TERMINAL
Connect to the 24 Vdc power supply, terminal 1
1 – 2
3 – 4
RESET button; connect a normally opened button (N.O.).
4 - 5
TEST button; connect a normally closed button (N.C.).
Connect the muting signaller.
6 - 7
8
Input of the muting B sensor.
Connect to the N.O. contact of the muting sensor (photocell, proximity switch, other).
Input of the muting A sensor.
9
Connect to the N.O. contact of the muting sensor (photocell, proximity switch, other).
10
Input of the muting D sensor.
Connect to the N.O. contact of the muting sensor (photocell, proximity switch, other).
Input of the muting C sensor.
11
Connect to the N.O. contact of the muting sensor (photocell, proximity switch, other).
12
Earth. Connect to the plant's earth.
(OUT1) safety output 1 with N.O. contact.
13 - 14
(OUT2) safety output 2 with N.O. contact.
15 - 16
17 - 18
Power supply to emitters (TX) of PES 1 and 2. Connect Vs wires (pin 1 of connector) to
terminal 17, and 0V wires (pin 3 of connector) to terminal 18.
Sending test signal to emitters (TX) of the safety PES 1 and 2; Connect test wire (pin 4 of
19 - 20
connector) of PES 1 to terminal 19, and that of PES 2 to terminal 20.
21 - 22
Power supply to emitters (TX) of PES 3 and 4. Connect Vs wires (pin 1 of connector) to
terminal 21, and 0V wires (pin 3 of connector) to terminal 22.
Sending test signal to emitters (TX) of the safety PES 3 and 4; Connect test wire (pin 4 of
23 - 24
connector) of PES 3 to terminal 23, and that of PES 4 to terminal 24.
25 - 26
Power supply to receivers (RX) of PES 1 and 2. Connect Vs wires (pin 1 of connector) to
terminal 25, and 0V wires (pin 3 of connector) to terminal 26.
Receiving PNP output from the receivers (RX) of safety PES 1 and 2: Connect PNP out
27 - 28
wire (pin 4 of connector) of PES 1 to terminal 27, and that of PES 2 to terminal 28.
29 - 30
Power supply to receivers (RX) of PES 3 and 4. Connect Vs wires (pin 1 of connector) to
terminal 29, and 0V wires (pin 3 of connector) to terminal 30.
Receiving PNP output from the receivers (RX) of safety PES 3 and 4: Connect PNP out
31 - 32
wire (pin 4 of connector) of PES 3 to terminal 31, and that of PES 4 to terminal 32.