Parameter List
Variable
CompoWay/F
Modbus
type
Category
Add-
Address
ress
E3 (A3)
Can be
Not used.
changed
0100
0360
while
stopped.
0101
0361
0102
0362
0103
0363
0104
0364
0105
0365
0106
0366
0107
0367
010E 036E
0115
0375
0116
0376
0117
0377
Not used.
0200
0560
0300
0760
0400
0960
Note The decimal point position is determined by the sensor selection. In this case, however, the 0 (****) dec-
imal point position setting will be treated as a setting of 1 (***.*).
Variable
CompoWay/F
Modbus
type
Category
Add-
Address
ress
E4 (A4)
Can be
0100
0380
changed
while
stopped.
0101
0381
0102
0382
0103
0383
0104
0384
0105
0385
0106
0386
Not used.
0200
0580
Parameter name
Alarm 1 Type - CH1
H' 00000000: Alarm function OFF (0)
H' 00000001: Upper and lower limit alarm (1)
H' 00000002: Upper limit alarm (2)
H' 00000003: Lower limit alarm (3)
H' 00000004: Upper and lower limit range alarm (4)
H' 00000005: Upper and lower limit alarm with standby
sequence (5)
H' 00000006: Upper limit alarm with standby sequence
(6)
H' 00000007: Lower limit alarm with standby sequence
(7)
H' 00000008: Absolute value upper limit alarm (8)
H' 00000009: Absolute value lower limit alarm (9)
H' 0000000A: Absolute value upper limit alarm with
standby sequence (10)
H' 0000000B: Absolute value lower limit alarm with
standby sequence (11)
H' 0000000C: LBA (Loop Burnout Alarm) (12)
Alarm 1 Latch - CH1
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
Alarm 1 Hysteresis - CH1
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note.)
Alarm 1 Open in Alarm - CH1
H' 00000000: Close in alarm (0)
H' 00000001: Open in alarm (1)
Alarm 1 ON Delay - CH1
H' 00000000 to H' 000003E7 (0 to 999)
Alarm 1 OFF Delay - CH1
H' 00000000 to H' 000003E7 (0 to 999)
Alarm 1 SP Selection - CH1
H' 00000000: Ramp SP (0)
H' 00000001: Target SP (1)
Alarm 2 Type - CH1
The rest are the same as Alarm 1.
Alarm 3 Type - CH1
LBA Detection Time - CH1
H' 00000000 to H' 0000270F (0 to 9999)
LBA Level - CH1
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note.)
LBA Band - CH1
H' 00000000 to H' 0000270F (0.0 to 999.9) (See note.)
Alarm 1 Type - CH2
The rest are the same as channel 1.
Alarm 1 Type - CH3
Alarm 1 Type - CH4
Parameter name
CT1 Assignment
H' 00000000: Disabled (0)
H' 00000001: Control output 1 (1)
H' 00000002: Control output 2 (2)
H' 00000003: Control output 3 (3)
H' 00000004: Control output 4 (4)
Heater Burnout 1 Latch
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
Heater Burnout 1 Hysteresis
H' 00000001 to H' 000003E8 (0.1 to 100.0)
HS Alarm 1 Latch
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
HS Alarm 1 Hysteresis
H' 00000001 to H' 000003E8 (0.1 to 100.0)
Heater Overcurrent 1 Latch
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
Heater Overcurrent 1 Hysteresis
H' 00000001 to H' 000003E8 (0.1 to 100.0)
CT2 Assignment
The rest are the same as from CT1 Assignment to
Heater Overcurrent 1 Hysteresis.
Setting (monitor) range
Setting (monitor) range
Appendix
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
HFU
TC2
2
---
ch
---
0
---
ch
---
0.2
EU
ch
---
0
---
ch
---
0
s
ch
---
0
s
ch
---
0
---
ch
---
0
s
ch
---
8.0
EU
ch
---
3.0
EU
ch
---
TC4
---
TC4
---
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
TC2
1
---
IO
TC2
---
0
---
IO
TC2
---
0.1
A
IO
TC2
---
0
---
IO
TC2
---
0.1
A
IO
TC2
---
0
---
IO
TC2
---
0.1
A
IO
TC2
---
2
249
HFU