Omron EJ1 User Manual page 269

Modular temperature controllers
Hide thumbs Also See for EJ1:
Table of Contents

Advertisement

Parameter List
Vari-
CompoWay/F
Modbus
able
Category
Add-
Address
type
ress
DA
Can be
0140
F040
(9A)
changed
during
0141
F041
opera-
tion.
0142
F042
0143
F043
0144
F044
0145
F045
0146
F046
0147
F047
0148
F048
0149
F049
(See
note
014A
F04A
2.)
014B
F04B
014C
F04C
014D
F04D
014E
F04E
014F
F04F
0150
F050
0151
F051
0152
F052
0153
F053
0154
F054
0180
F080
0181
F081
0182
F082
0183
F083
0184
F084
0185
F085
0186
F086
0187
F087
0188
F088
0189
F089
018A
018B
018C
01C0
F08A
01C1
F08B
01C2
F08C
01C3
F0C0
01C4
F0C1
01C5
F0C2
01C6
F0C3
01C7
F0C4
01C8
F0C5
01C9
F0C6
01CA
F0C7
01CB
F0C8
244
Parameter name
G3ZA1 - CH1 Control Variable Monitor
G3ZA1 - CH2 Control Variable Monitor
G3ZA1 - CH3 Control Variable Monitor
G3ZA1 - CH4 Control Variable Monitor
G3ZA1 - CH1 Status
G3ZA1 - CH2 Status
G3ZA1 - CH3 Status
G3ZA1 - CH3 Status
G3ZA1 - CT1 Effective Current Monitor
G3ZA1 - CT2 Effective Current Monitor
G3ZA1 - CT3 Effective Current Monitor
G3ZA1 - CT4 Effective Current Monitor
G3ZA1 - CT1 Heater ON Current Monitor
G3ZA1 - CT2 Heater ON Current Monitor
G3ZA1 - CT3 Heater ON Current Monitor
G3ZA1 - CT4 Heater ON Current Monitor
G3ZA1 - CT1 Heater OFF Current Moni-
tor
G3ZA1 - CT2 Heater OFF Current Moni-
tor
G3ZA1 - CT3 Heater OFF Current Moni-
tor
G3ZA1 - CT4 Heater OFF Current Moni-
tor
Version
G3ZA1 - Send Standby Time (See note 1.)
G3ZA1 - Communications Timeout Time
(See note 1.)
G3ZA1 - Setting Operation for Errors
G3ZA1 - Offset Value
G3ZA1 - Hysteresis
G3ZA1 - SSR Drive Selection
G3ZA1 - Current Monitor Display Selec-
tion
G3ZA1 - Communications Hysteresis
G3ZA1 - Communications Timeout Time
2 (See note 1.)
G3ZA1 - CT1 Assignment (See note 1.)
G3ZA1 - CT2 Assignment (See note 1.)
G3ZA1 - CT3 Assignment (See note 1.)
G3ZA1 - CT4 Assignment (See note 1.)
G3ZA1 - CH1 Soft Increase Time
G3ZA1 - CH2 Soft Increase Time
G3ZA1 - CH3 Soft Increase Time
G3ZA1 - CH4 Soft Increase Time
G3ZA1 - CH5 Soft Increase Time
G3ZA1 - CH6 Soft Increase Time
G3ZA1 - CH7 Soft Increase Time
G3ZA1 - CH8 Soft Increase Time
G3ZA1 - CH1 Soft Decrease Time
G3ZA1 - CH2 Soft Decrease Time
G3ZA1 - CH3 Soft Decrease Time
G3ZA1 - CH4 Soft Decrease Time
Setting (monitor) range
H' 00000000 H' 000003E8 (0.0 to 100.0)
V2
H' 00000000 H' 000003E8 (0.0 to 100.0)
V2
H' 00000000 H' 000003E8 (0.0 to 100.0)
V2
H' 00000000 H' 000003E8 (0.0 to 100.0)
V2
---
V2
---
V2
---
V2
---
V2
H' 00000000 H' 00000672 (0.0 to 165.0)
V2
H' 00000000 H' 00000672 (0.0 to 165.0)
V2
H' 00000000 H' 00000672 (0.0 to 165.0)
V2
H' 00000000 H' 00000672 (0.0 to 165.0)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
H' 00000000 to H' 000000A5 (0 to 165)
V2
---
V2
H' 00000000 to H' 00000063 (0 to 99)
H' 00000000 to H' 0000003C (0 to 60)
(Function stops when set to 0.)
H' 00000000: Continue with error clear (0)
H' 00000001: Continue without error clear (1)
H' 00000002: Stop (2)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000001 to H' 0000000A (1 to 10)
H' 00000000: Zero-cross SSR for single-phase
V2
heater, optimum cycle control (0)
H' 00000001: Non-zero-cross SSR for single-
phase heater, soft-start optimum cycle control
(1)
H' 00000002: Zero-cross SSR for three-phase
heater, three-phase optimum cycle control (2)
H' 00000000: 0 to 50 A (0)
V2
H' 00000001: 0 to 150 A (1)
H' 00000002: 0% to 100% (2)
H' 00000000 to H' 0000012C (0.0 to 30.0)
V2
H' 00000000: Disabled
V2
H' 00000001 to H' 00000E10 (1 to 3600)
H' 00000000: Disabled (0)
V2
H' 00000001: ch1 (1)
H' 00000002: ch2 (2)
V2
H' 00000003: ch3 (3)
H' 00000004: ch4 (4)
V2
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
H' 00000000 to H' 000003E7 (0.0 to 99.9)
V2
Appendix
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
HF
TC2
U
0.0
%
NUM
---
0.0
%
NUM
---
0.0
%
NUM
---
0.0
%
NUM
---
---
---
NUM
---
---
---
NUM
---
---
---
NUM
---
---
---
NUM
---
0.0
A/%
NUM
---
0.0
A/%
NUM
---
0.0
A/%
NUM
---
0.0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
0
A/%
NUM
---
---
---
NUM
---
1
ms
NUM
---
0
min
NUM
---
0
---
NUM
---
20.0
%
NUM
---
1
A
NUM
---
0
---
NUM
---
0
---
NUM
---
1.0
%
NUM
---
0
s
NUM
---
1
---
NUM
---
2
---
NUM
---
3
---
NUM
---
4
---
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
20.0
s
NUM
---
0.0
s
NUM
---
0.0
s
NUM
---
0.0
s
NUM
---
0.0
s
NUM
---

Advertisement