Section 4

Communications Timing

Communications Timing
Communications Timing
This appendix describes the internal processing times for the communication unit.
For details of communication times for DeviceNet master, refer to the relevant user's
manuals.
■ Maximum ON/OFF Output Data Input Delay Time
The maximum delay time is as follows:
• With up to 8 Sensors connected:
Maximum ON/OFF output data input delay time for Unit n = 0.1 x n + 2.5 (ms)
• With 9 or more Sensors connected:
Maximum ON/OFF output data input delay time for Unit n = 0.2 x n + 2.5 (ms)