Omron E3X-DRT21-S User Manual page 53

E3x-da-s series, e3x-mda series communication unit for digital type sensor
Hide thumbs Also See for E3X-DRT21-S:
Table of Contents

Advertisement

● Read the detection level/read the detection level on detected (ON)/
read the detection level on undetected (OFF)
These commands read the detection level of the sensor with the unit No. specified with
the Instance ID.
Those data is shown in hexadecimal as a four-digit value (two bytes).
If the data is negative, the 12th bit is 1 (on).
Detection level
Bit
Bit
Bit
Bit
15
14
13
12
0:
+
0 Fixed
/
1:
-
Read Detection level on Detected (ON) and Read Detection level on Undetected (OFF)
can read the detection level only when the display switching settings are peak on
detected and bottom on undetected.
Also, its data range is between F831Hex (complement of 2) and 0FA0Hex.
● Read detection level + ON/OFF output
It reads the detection level of the sensor with the unit No. specified with the Instance ID.
The data is shown in hexadecimal as a four-digit value (two bytes).
If the data is negative, the 12th bit is 1 (on).
Detection level + ON/
OFF output
Bit
Bit
Bit
Bit
15
14
13
12
0:
+
0
*1
*2
/
Fixed
1:
-
Bit
Bit 14 (*2)
External input data
Bit 15 (*1)
ON/OFF output data
Bit
Bit
Bit
Bit
Bit
11
10
09
08
07
The detection level (000Hex to FA0Hex)
Bit
Bit
Bit
Bit
Bit
11
10
09
08
07
The detection level (000Hex to FA0Hex)
Description
0: No external input, 1: External input
0: OFF, 1: ON
Explicit Message Communications
Bit
Bit
Bit
Bit
Bit
06
05
04
03
02
Bit
Bit
Bit
Bit
Bit
06
05
04
03
02
Data
Section 3
Bit
Bit
01
00
Bit
Bit
01
00
E3X-DRT21-S
51
User's Manual