[ServiceCode]
When the command is completed normally, the leftmost bit of the [ServiceCode]
specified in the command is turned ON and stored as follows:
ServiceCode of the Command
10 Hex
0E Hex
16 Hex
06 Hex
07 Hex
05 Hex
When an error message is returned to the Explicit message, the value always will be
94Hex.
[Data]: The read data is stored only when a read command has been sent.
[Error Code]: An error code for the Explicit message.
"Error Code List" on p. 72
• For the Communication Unit, set the DeviceNet message monitoring timer to 20 seconds or
more. The setting method is as follows:
(1) For CS1W-DRM21 and CJ1W-DRM21
You can set the following by using the Configurator:
1. Switch the Configurator to online.(select [Network] - [Connection])
2. Select either CS1W-DRM21 or CJ1W-DRM21, and then double-click it.
3. Set the monitoring timer for the node of the communication unit to 20,000 ms.
4. Set the response monitoring timer in [CMND] commands, which sends Explicit messages, to
20,000 ms or more.
(2) For C200HW-DRM21 and CVM1-DRM21
1. Set the response monitoring timer in [IOWR] commands, which send Explicit messages, to
20,000 ms.
(The message monitoring timer does not need to be set with the Configurator.)
Explicit Message Communications
ServiceCode of the Response
90 Hex
8E Hex
96 Hex
86 Hex
87 Hex
85 Hex
Section 3
E3X-DRT21-S
45
User's Manual