Section 3
Explicit Message Communications
Explicit Messages
ON-Delay and OFF-
Delay timerRead
ON-Delay timer time
Settings
ON-Delay and OFF-
Delay timerRead
OFF-Delay timer
time Settings
Read Display
Switching Settings
Read MODE Key
Settings
Read Display
Direction Settings
Read Power Tuning
Target Value Settings
Read Output
Settings
Read Output Settings
Timer Function
Read Output
Settings Timer Time
Read External Input
Settings
Read External Input
Memory Settings
Read Teaching
Level Settings
without a Workpiece
Read Counter
Settings
Read Counter Value
(Upper) Settings
Read the Counter
Value (Lower)
Settings
Read Counter Value
(Upper)
Read Count Value
(Lower)
E3X-DRT21-S
48
User's Manual
Functions
With specifying a Unit No. with the Instance
ID, reads the ON-Delay timer time.
With specifying a Unit No. with the Instance
ID, reads the OFF-Delay timer time.
With specifying a Unit No. with the Instance
ID, reads the display switching settings.
With specifying a Unit No. with the
Instance ID, reads the MODE key
settings.
With specifying a Unit No. with the
Instance ID, reads the display direction
settings.
With specifying a unit No. with the Instance
ID, reads the power tuning target value.
With specifying a Unit No. with the
Instance ID, reads the output settings.
With specifying a Unit No. with the Instance
ID, reads the output settings timer function.
With specifying a Unit No. with the Instance
ID, reads the output settings timer time.
With specifying a Unit No. with the
Instance ID, reads the input settings.
With specifying a Unit No. with the Instance
ID, reads the external input memory
settings.
With specifying a Unit No. with the
Instance ID, reads the teaching level
settings without a workpiece.
With specifying a Unit No. with the
Instance ID, reads the counter settings.
With specifying a Unit No. with the Instance
ID, reads the counter value (upper)
settings.
With specifying a Unit No. with the
Instance ID, reads the counter value
(lower) settings.
With specifying a Unit No. with the Instance
ID, reads the count value (upper four
digits).
With specifying a Unit No. with the Instance
ID, reads the count value (lower four digits).
Command
Class
Instance
Attribute
ID
ID
ID
9C
Unit
E6
Number
9C
Unit
E7
Number
9C
Unit
26
Number
9C
Unit
27
Number
9C
Unit
28
Number
9C
Unit
29
Number
9C
Unit
2A
Number
9C
Unit
2B
Number
9C
Unit
2D
Number
9C
Unit
2C
Number
9C
Unit
2E
Number
9C
Unit
4B
Number
9C
Unit
2F
Number
9C
Unit
30
Number
9C
Unit
31
Number
9F
Unit
84
Number
9F
Unit
85
Number
Supported
Model
DA7
DA7
All models
All models
All models
Except EDATW
and EDARM
DA7, TW, MDA,
LDATW, EDATW
MDA
MDA
RM, LDARM,
EDARM
RM, LDARM,
EDARM
All models
RM,
LDARM
RM,
LDARM
RM,
LDARM
RM,
LDARM
RM,
LDARM

Advertisement

Table of Contents
loading