4
Press the voltage knob to determine
enabled or disabled.
When the settings are confirmed, "ConF"
will be displayed.
Delay time setting
5
Rotate the Voltage knob to change the F
setting to F-A1.
F-A1: tUVP function delay time setting
6
Rotate the current knob to delay time
setting.
Setting Range: 0.1s ~ 60.0s
7
Press the voltage knob to determine
delay time setting.
When the settings are confirmed, "ConF"
will be displayed.
Voltage drops value setting
8
Rotate the Voltage knob to change the F
setting to F-A2.
F-A2: tUVP function voltage drops value
setting
9
Rotate the current knob to delay time
setting.
Setting Range: 0.01 or 0.1V ~ Rated
voltage
Note
10
Press the voltage knob to determine
voltage drops value.
When the settings are confirmed, "ConF"
will be displayed.
11
Press the Function key to finish this function setting.
The Function key turns off.
The setting range varies depending on the minimum digit
of the power module voltage display. Models with a
minimum digit of 10mV will have a value of ``0.01,'' and
models with a minimum digit of 100mV will have a value of
``0.1.''