Table 2 Inverter Mode Specifications
MODEL
Rated Output Power
Output Voltage Waveform
Output Voltage Regulation
Output Frequency
Peak Efficiency
Overload Protection
Surge Capacity
Optional 12V DC Output
DC Output
High DC Cut-off Voltage
Low DC Cut-off Voltage
Nominal DC Input Voltage
Cold Start Voltage
Low DC Warning Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Warning Return Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
High DC Cut-off Voltage
DC Voltage Accuracy
THDV
DC Offset
100ms@≥205% load;5s@≥150% load; 10s@110%~150% load
2* rated power for 5 seconds
12 VDC ± 7%, 100W
+/-0.3V@ no load
40
PIP8048MAX
8000W
Pure Sine Wave
230Vac± 5%
60Hz or 50Hz
>97%
66Vdc
44Vdc
48Vdc
46.0Vdc
46.0Vdc
42.8Vdc
40.4Vdc
48.0Vdc
44.8Vdc
42.4Vdc
44.0Vdc
40.8Vdc
38.4Vdc
64Vdc
66Vdc
<3% linear
≦100mV