MPP Solar 8048MAX 2 Series User Manual page 25

Solar inverter / charger
Table of Contents

Advertisement

Reset all stored data for PV
37
generated
power
output load energy
Maximum
41
discharging current
On/Off control for RGB LED
*It's necessary to enable
51
this setting to activate RGB
LED lighting function.
52
Brightness of RGB LED
Not reset(Default)
and
Disable (Default)
30A
battery
150A
Enabled (default)
Low
High
23
Reset
If selected, battery discharge
protection is disabled.
The setting range is from 30 A to
150 A. Increment of each click is
10A.
If discharging current is higher
than setting value, battery will
stop discharging. At this time, if
the utility is available, the
inverter will operate in bypass
mode. If no utility is available,
the inverter will shut down after
5-minute operation in battery
mode.
Disable
Normal (default)