The DST1-series Safety I/O Terminals support the DeviceNet Safety protocol and provide various functions
for the Safety System. The DST1-series Safety I/O Terminals allow the user to construct a safety control/
network system that meets the requirements for Safety Integrity Level (SIL) 3 according to IEC 61508 (Func-
tional Safety of Electrical/Electronic/ Programmable Electronic Safety-related Systems) and the require-
ments for Safety Category 4 according to EN 954-1.
The DST1-series Safety I/O Terminal's safety I/O data is transmitted through safety I/O communications con-
forming to the DeviceNet Safety Protocol, and the data processing is performed in conducted in the Safety
Network Controller (NE1A-SCPU01). Also, the status of the safety I/O data can be monitored in a standard
PLC in an existing DeviceNet network using standard I/O communications or explicit message communica-
tions.Dual Channel Complementary
DST1-series
Safety I/O Terminal
Emergency Stop
Button
1-1-2

DST1-series Safety I/O Terminals Features

Safety Inputs
Semiconductor output devices such light curtains can be connected as well as contact output devices
such as emergency stop switches.
Faults in external wiring can be detected.
Input delays (ON delays and OFF delays) can be set.
Pairs of related local inputs can be set to Dual Channel Mode in order to be compliant with the Category
4 standards.
When Dual Channel Mode is set, the input data patterns and the time discrepancy between input sig-
nals can be evaluated.
Test Outputs
4 independent test outputs are available to use.
A disconnected external indicator lamp can be detected. (Can be set for the T3 Terminal only.)
Test outputs can be used as power supply terminals to devices such as sensors.
Test outputs can be used as the standard output terminals for monitor outputs.
Safety Outputs
Semiconductor Outputs
Pairs of related local outputs can be set to Dual Channel Mode in order to be compliant with the Cate-
gory 4 standards.
When Dual Channel Mode is set, the output data patterns can be evaluated.
The rated output current is 0.5 A max. per output.
20
Network Configurator
DeviceNet Network
Two-hand Switch
Safety Door Switch
Safety Limit Switch
Safety Network Controller
DST1-series
Safety I/O Terminal
Enable Switch
Safety Light Curtain
PLC
DeviceNet Master
Contactor
Safety Relay
Valve
Safety Relay Unit