Muting Lamp Output; Limit Switch Dual Channel Inputs And A Manual Reset - Omron DEVICENET SAFETY - 04-2005 Operation Manual

Safety i/o terminals
Table of Contents

Advertisement

7-2-4

Muting Lamp Output

An example of the wiring and configuration when using the DST1-ID12SL-1 is shown below.
Wiring
Configuration
Parameter group
Test Output 3
7-2-5

Limit Switch Dual Channel Inputs and a Manual Reset

An example of the wiring and configuration when using the DST1-ID12SL-1 is shown below.
Wiring
V
G
E1
GND
Configuration
Parameter
group
Safety Input 0 0008
Safety Input 1 0012
Safety Input 11 0052
Test Output 0 0001
Test Output 1 0002
Test Output 2 0003
7-2 Examples of Wiring for Each Application
V
G
E1
GND
Parameter name
0004
Test Output 3 Mode
IN0
IN1
T0
T1
11
S 1
12
23
S 2
24
Param
Value
eter
name
Safety Input 0 Channel Mode
0009
Safety Input 0 Test Source
0054
Dual Channel Safety Input 0/1 Mode
0055
Dual Channel Safety Input 0/1 Discrepancy Time 100 x 10 ms
Safety Input 1 Channel Mode
0013
Safety Input 1 Test Source
Safety Input 11 Channel Mode
0053
Safety Input 11 Test Source
0064
Dual Channel Safety Input 10/11 Mode
Test Output 0 Mode
Test Output 1 Mode
Test Output 2 Mode
E1: 24-V DC Power Supply (S8@@)
L1: External muting lamp
T3
G
X
L1
IN
T2
11
E1: 24-V DC Power Supply (S8@@)
S1: Safety Limit Switch (D4D or D4B)
T1
G
(positive opening mechanism)
S2: Limit switch
S3: Reset switch
S3
Value

Muting Lamp Output

Test pulse from test output
Test Output 0
Dual Channel Equivalent
Test pulse from test output
Test Output 1
Used as standard input
Not Used
Single Channel
Pulse Test Output
Pulse Test Output
Power Supply Output
83