System Configuration
1-2-5 One-to-one NT Link Communications

1-2-6 CompoBus/S I/O Link Connections

SYSMAC CS-series PC
Using the NT Link, the CPM1A PC can connected to the Programmable Termi-
nal (NT Link Interface) through an RS-232C Adapter.
OMRON Programmable Terminal
Name
RS-232C Adapter
Converts to peripheral port-level
communications.
A CompoBus/S I/O Link can be used to create an I/O link (remote I/O) of 8 input
points and 8 output points with a CompoBus/S Master Unit or SRM1 PC. The
connection is made through a CompoBus/S I/O Link Unit.
From the standpoint of the CPM1A CPU Unit, the area allocated to the Compo-
Bus/S I/O Link Unit can be treated just like the area allocated to an Expansion I/O
Unit. The difference is that the bits are not actual I/O points, but I/O bits in the
Master Unit.
CompoBus/S Master Unit (or SRM1 PC)
CPM1A CPU Unit
(with 30 or 40 I/O points)
Cables
Use special flat cable, VCTF 2-core cable, or VCTF 4-core cable. Do not com-
bine different types of cable in the same system.
Name
Flat cable
4-core flat cable, 0.75 mm
VCTF cable
2-core x 0.75 mm
RS-232C
Adapter
RS-232C Cable
WX2Z-200T (2 m)
WX2Z-500T (5 m)
Usage
CompoBus/S I/O Link Unit
Specifications
2
2
2
, 4-core x 0.75 mm
(JIS C3306)
Section 1-2
CPM1A CPU Unit
Model number
CPM1-CIF01
(Slave)