Omron CJ1W-MA - REV 10-2008 Operation Manual page 152

Position control units
Table of Contents

Advertisement

Servo Parameter Area
Param-
Parame-
Param-
eter No.
ter name
eter
size
Pn505
Deviation
2
counter
overflow
level
Pn506
Brake tim-
2
ing 1
Pn507
Brake
2
command
speed
Pn508
Brake tim-
2
ing 2
Pn509
Momen-
2
tary hold
time
Contents
Digit
Name
Set-
No.
ting
Sets the detection level for the deviation counter over
alarm.
Sets the delay from the brake command to the Servo-
motor turning OFF.
Sets the rotation speed for outputting the brake com-
mand.
Sets the delay from the Servomotor turning OFF to
the brake command output.
Sets the time during which alarm detection is disabled
when a power failure occurs.
Default
Unit
setting
Explanation
× 256
1024
pulses
× 10
0
ms
100
r/min
× 10
50
ms
20
ms
Section 4-5
Setting
Enable
Details
range
setting
1 to
Online
---
32767
0 to 50
Online
---
0 to
Online
---
10000
10 to
Online
---
100
20 to
Online
---
1000
125

Hide quick links: