2.4 Use ..........................7 3 Description of the product ....................3.1 Intended use ........................ 8 3.2 Knee control unit K-Control TLC 4955 ................9 3.3 Foot control unit K-Control TLC 4956 ................10 3.4 Table top control K-Control TLC 4957................11 3.5 Rating plates ........................
This document is for dental technicians and laboratory personnel. 1.1 Terms and conditions of warranty KaVo provides the final customer with a warranty that the product cited in the transfer form will function properly and guarantees zero defects in the material...
Page 6
Claims from this warranty can only be asserted when the transfer form (copy) belonging to the product has been sent to KaVo, and the original can be presented by the operator or user. 6 / 32...
Instructions for use K-Control TLC 4955 4956 4957 2 Safety | 2.1 Explosion 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
Any waste produced must be recycled or disposed of in strict compliance with all applicable national regulations in a manner which is safe for both people and the environment. If you have any questions regarding the proper disposal of the KaVo product, please contact the KaVo branch office. 8 / 32...
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.2 Knee control unit K-Control TLC 4955 3.2 Knee control unit K-Control TLC 4955 Knee control unit K-Control TLC 4955 ① Speed, torque and program selec- ②...
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.3 Foot control unit K-Control TLC 4956 3.3 Foot control unit K-Control TLC 4956 Foot control unit K-Control TLC 4956 ① Display with LEDs and bar indicat- ②...
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.4 Table top control K-Control TLC 4957 3.4 Table top control K-Control TLC 4957 Table top control K-Control TLC 4957 ① Speed, torque and program selec- ②...
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.6 Technical Specifications Material number VDE mark CSA mark Do not dispose of with household waste Operating mode GS mark HIBC Code MET mark EAC conformity mark (Eurasian Conformity) CE- mark (European Community).
Page 13
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.6 Technical Specifications Rated voltages Voltage range 100 to 240 V AC, 50 to 60 Hz Rated power max. 220 W Overvoltage category Line voltage fluctuations ±...
Instructions for use K-Control TLC 4955 4956 4957 3 Description of the product | 3.7 Scope of delivery NOTE Prior to putting into service, very cold products must be heated to a temper- ature of 20°C to 25°C. Avoid condensation.
Instructions for use K-Control TLC 4955 4956 4957 4 Startup | 4.1 Combined control/handpiece 4 Startup NOTE Prior to putting into service, very cold products must be heated to a temper- ature of 20°C to 25°C. Avoid condensation. NOTE Do not switch the handpiece on while the chuck is open! NOTE Do not cover the air vent.
4.3 Location NOTE This KaVo product must be set up on a level, stable, horizontal surface and its secure footing must be ensured. Do not set up right next to the edge of the table. Connecting cables, connections to motorised handpieces and foot con- trol must be routed safely.
Instructions for use K-Control TLC 4955 4956 4957 4 Startup | 4.3 Location 4 Insert the power plug into an appropriate, easily accessible and properly in- stalled and grounded mains socket outlet. NOTE The knee control is attached to the mounting bracket. To remove it, you need to tug the knee control towards you and take it out of the bracket.
Page 18
Instructions for use K-Control TLC 4955 4956 4957 4 Startup | 4.3 Location 4 Insert the power plug into an appropriate, easily accessible and properly in- stalled and grounded mains socket outlet. NOTE The device is separated from the supply mains by pulling out the mains or device plug.
Page 19
Instructions for use K-Control TLC 4955 4956 4957 4 Startup | 4.3 Location 4 Plug in the connecting cable to the handpiece and 4620 pedal switch and screw it tight. 4 Insert the power plug into an appropriate, easily accessible and properly in- stalled and grounded mains socket outlet.
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5 Operation NOTE Note the safety instructions before each use. NOTE The device should be set up so that the power disconnection device can be easily accessed. Be aware of intermittent operation! HAZARD Explosion.
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.1 Operating the knee control and tabletop control CAUTION Premature wear and malfunctions from improper care. Reduced product life. 4 Use recommended care products only. CAUTION Risk due to incorrectly stored handpiece.
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.1 Operating the knee control and tabletop control 5.1.1 Controls on the knee control and table-top control Controls on the knee control and table-top control ① Speed, torque and program selec- ②...
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.1 Operating the knee control and tabletop control 5.1.3 Setting the speed 4 Press the speed preset button to activate the speed setting function. ð The button's LED lights up.
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.2 Operating the foot control unit ð The display flashes once. 5.2 Operating the foot control unit 5.2.1 Controls on the foot control Operating the foot control unit ① Bar indicator for speed ②...
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.3 Operation in KaVo suction systems Also refer to: 5.2.6 Calling up programs, Page 25 5.2.4 Setting the torque 4 Press the torque selection button briefly several times in succession to set the max.
Page 26
Instructions for use K-Control TLC 4955 4956 4957 5 Operation | 5.3 Operation in KaVo suction systems Connect control units K-Control TLC with control line (Mat. no. 1.000.7198) to SMARTair 26 / 32...
▪ the applicable accident prevention regulations. The overarching guidelines and/or national laws, national regulations and the rules of technology applicable to this product for start-up and use of the KaVo product for the indications for use are to be applied and complied with.
Instructions for use K-Control TLC 4955 4956 4957 7 Troubleshooting 7 Troubleshooting NOTE On the knee control and table top control, the error display is shown on the display together with the word "ERROR". The speed and torque displays will be hidden by this text.
Instructions for use K-Control TLC 4955 4956 4957 8 Accessories 8 Accessories Presentation Material summary Material number Pedal switch 0.617.0460 Handpiece rest 1.005.3460 Control line 1.000.7198 29 / 32...
Instructions for use K-Control TLC 4955 4956 4957 9 Declaration of conformity 9 Declaration of conformity EC-Declaration of Conformity EG-Konformitätserklärung CE-Déclaration de conformité Dichiarazione di conformità con le norme CE Prohlášení o shodě s normami ES Declaración de Conformidad de la CE...