Triple-interval high precision
counting scale (15 pages)
Summary of Contents for UWE ADW-E-II
Page 1
ADW-E-II ADW-C-II OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING UNIVERSAL WEIGHT ELECTRONICS | UWE-EUROPE.COM...
Page 2
CAUTIONS 1. This unit is legal for trade only when it is sealed (and/or stamped) and bearing a serial number. Do not attempt to break the seal (or stamp) affixed to this scale or remove the serial number. Contact your dealer for more information and after-sales service.
INSTALLATION Power on the scale SPECIFICATIONS RESOLUTION SPECIFICATION KEYBOARD LAYOUT AND DESCRIPTION PANEL Instructions Select weight units Tare Setting How to cancel the tare value Disabling the Auto Tare Function Accumulation Function (M+) Storing Weighing Results into Memory: Memory Recall Mode: Clearing All Accumulated Results: Deleting a Specific Accumulated Entry: Counting Mode...
INSTALLATION What’s in the box? Scale x 1 Plastic platter x 1 Stainless steel cover x 1 Screw x 1 Rubber cap x 1 Power adaptor x 1 Contact your dealer if any item is missing. FIG 1...
(FIG 2 E) to seal the DC input jack of scale. SPECIFICATIONS RESOLUTION SPECIFICATION Division Non-OIML Platter Model Capacity (e2/e1) division size (mm) Rating Setup Dual ADW-E-II 1.5/3 kg 0.5/1 g 0.2 g 215 x 250 IP68 interval...
Page 6
Dual ADW-E-II 3/6 kg 1/2 g 0.5 g 215 x 250 IP68 interval Dual ADW-E-II 6/15 kg 2/5 g 215 x 250 IP68 interval Dual ADW-E-II 15/30 kg 5/10 g 215 x 250 IP68 interval Division Non-OIML Platter Model Capacity...
KEYBOARD LAYOUT AND DESCRIPTION PANEL Symbols Description Indicates that the current measurement status is at the "zero" →0← point when displayed. When displayed, it indicates that the current value shown is the net weight. ◣◢ (Stable) Displayed when the scale is in a balanced and stable state. Shows the battery's level of charge.
Page 8
These indicators display whether a weight is below (LO), within HI-OK-LO (OK), or above (HI) a preset range. Charging Status Red indicates that the battery is charging, green signifies that Indicator Light charging is complete. For settings related to the IR Sensor, refer to the internal setting menu F51.
This key is used to retrieve the accumulated total weight result from the internal memory. MR ⇩ In the parameter setting mode, it lets you move down or decrease the numerical value by 1, or move left. Instructions ● Place this scale on a solid flat surface, make sure that the environment has no strong wind/vibration/radio interference.
Automatically tares each stable weight placed on the scale. If Continuous Auto Tare check weighing function is enabled, auto tare is performed when (tr.Cnt) the result falls within the acceptable range. Automatically tares the first stable weight placed on the scale. Package Tare Auto tare activates when check weighing function is enabled and (tr.Pack)
2. The same unit of measurement must be used for all weighings. 3. The Accumulation Function can accommodate up to 999 entries or a total value of 999,999. Storing Weighing Results into Memory: Place your load on the scale. Wait for the "stable" indicator ◣◢ to appear on the display.
Choose 'PCS' as your unit of measurement by Unit of measurement shows pressing [MODE] "PCS" Initiate the sampling mode by long pressing Displays "S---" [ZERO⇨] Input the quantity of pieces in your sample batch. Increase the quantity with [MODE⇧], The input quantity is displayed decrease with [MR⇩], and shift to the next digit with [ZERO⇨] Put the sample batch on the scale...
Page 13
To deactivate, either press ZERO (⇨) or allow the system to time out after 8 seconds. If activated, the display shows "PrEV". Press TARE (↵) to use previous settings, or press ZERO (⇨) to PrEV set new values. Setting Limits Step Display Action...
● Measurement Units: Check Weighing can be used in g, kg, lb. PCS ● Minimum Activation: 20d in weighing mode, 2pcs in counting mode. ● Limit Validation: Lower limit must be less than the upper limit. Percentage Weighing Use the percentage mode to measure the weight of a reference item, then display the weight of the test item as a percentage of the reference item's weight.
Internal Setting Function The table below lists the internal functions available, some of which are only authorized for technical personnel. Do not attempt to disassemble any certified scales or any sealed structures Display Function Setting Access (Note 1) Password or Legal F0 * Zero tracking parameter setting (0.25/0.5/1.0/2.0d) restrictions...
Page 16
Specification setting (for trade/ maximum weighing + Password or division value/calibration) hardware lock control Auto shutdown setting (ALL.on or wait minutes) Open (uncontrolled) Measurement unit menu (on/OFF + kg/lb/g….) Open (uncontrolled) Digital filter parameter selection (anti-shock intensity Open (uncontrolled) 0~6 level) UART1: Communication protocol setting of serial Open (uncontrolled) communication interface...
Password or Legal F33* Key Stability Control restrictions Zero near residual weight zeroing range [ 0 /1/2/3/5 d Password or Legal F35* restrictions Password or Legal F36* Weight value drift compensation [0.0~2.0d] restrictions Power saving function (backlight on time Off / Open (uncontrolled) 5/10/20/ON) IR SENSOR Setting &...
Page 18
Before the countdown ends, press the [TARE] key to Displays "F1" or "F0" enter internal settings mode. Use [▲] key to go to next option or [▼] key to go back The next or previous to previous option. option is displayed Confirm your selection and enter the parameter The parameter settings settings of the selected function by pressing the...
Page 19
Definition: If the scale is idle for a certain duration (no weight change or operation), the auto- shutdown mechanism is triggered to conserve power. You can select the auto-shutdown wait time or disable this feature entirely by choosing between ALL.on -> 5.oFF -> 10.oFF -> 20.oFF ->...
Page 20
Enter RS-232 Press [TARE] when F8 is This opens the menu for external device Configuration displayed. selection. Choose PC (Computers) / TSC The type of device you're connecting to. Use [▲]/[▼] to select and [TARE] to External (Label Printers) / SH-24 Device (24-Pin Dot Matrix Printers) confirm.
Page 21
WEIGHT (kg) UT Remarks 100.02 H Press [M+/MC] to send data 99.01 G 1210.05 H 10.12 L Press [MR] then [M+/MC] to send the Total 9876.10 total weight and clear the weight from memory AUTO: Automatic Transmission Modes Format Set to Ser1.x: In this automatic mode, the data will be transmitted once the weighing result is stable.
Page 22
Format Set to Ser1.x: 2022/07/25 10:30:21 ST, NT, 100.01 g 2022/07/25 10:30:39 ST, NT, 210.00 g Format Set to Ser2.x: The date and time precede the weight data table, which shows individual and total weights. Date & Time: 2022/07/25 10:31:21 WEIGHT (g) 100.02 99.01...
Page 23
one minute and then shut off. If the overload is removed during this period, the scale will zero and enter standby mode. Settings Functionality Based on the calibration zero point, there are no restrictions, and it goes In.= OFF straight into standby mode showing the current weight. Based on the calibration zero point, only if the load is within ±20% of the In.= 20 maximum weight capacity, will it allow for initial zero-setting and...
Page 24
change is within (display value); Range: a certain Unlocks when ±0.1% to percentage of more than ± x%; ±20.0% the display Locks again when (display value less than ± x% value) Only the Force measurement or maximum measuring breaking weight value Resets after Peek.H strength of ropes...
Page 25
If you don't want to change This option allows you to abort the the password, press [⇦] to password change operation exit Enter old password (up to 6 Use the [▲] or [▼] key to increase digits), then press [ ↵] XXXX or decrease the old password value, then press the confirmation key "".
Page 26
Quick Guide: Steps Choices Controls Actions [▼ or ▲] 1. Activate RTC [rtC.on] / [rtC.oFF] Toggle RTC on or off [yy:mm:dd] / 2. Choose Date [▼ or ▲] [dd:mm:yy] / Select format Format [mm:dd:yy] [▲ or ▼] to change the value, [►] to 3.
Page 27
Definition: This setting controls the automatic reset to zero for residual display values near the zero point. These residual values could be due to inherent properties of the load cell, signal offsets, or span. They may persist particularly in high-resolution settings (n>30,000d). Options: [F35] ->...
Maintenance and Care Guidelines ● Do not attempt to open or repair the scale yourself; seek assistance from qualified technicians. ● Keep an eye on the operating environment to avoid excessive humidity and extreme temperatures. ● Use the provided original charger for charging purposes. ●...
Need help?
Do you have a question about the ADW-E-II and is the answer not in the manual?
Questions and answers