Handoff Procedures

Combined changes

These parameters can be combined in
any way for handoff procedures
Analog TC
Digital TC
FVC
DTC
SAT FREQ
DVCC
POWER LEVEL
SLOT
POWER LEVEL
TIME ALIGNMENT
Rate
Examples:
1)
The mobile is in a digital TC. Change DTC, DVCC, SLOT, POWER
LEVEL, TIME ALIGNMENT and Rate; this is the most complex handoff in
the digital mode of a mobile.
2)
The mobile is in an analog TC. Change FVC, SAT FREQ and POWER
LEVEL; this is the most complex handoff in the analog mode of a mobile.
3)
Of course it is possible to change from an analog TC to a digital one and
vice versa.
Besides simple handoff procedures
(changing a single parameter), com-
plex handoff procedures are also per-
missible (changing several parameters
at the same time). In earlier versions of
(E)AMPS test programs there were im-
permissible parameter combinations.
There is no such restriction in the IS-
136 MS-TEST program: all parameters
allowed in handoff procedures can be
changed in any combination.
IS-136 MS