Handoff Procedures
Change SAT
WHY?
Requirement
HOW?
A
Fig. 10.12: SAT has two major functions in
AMPS radio networks:
a) SAT frequency serves mobile and base
station for mutual recognition.
b) Phase drift results when mobile is moving.
From this base station is able to detect
whether mobile is moving away fast, for
example, and power level should be in-
creased.
Test whether the mobile switches to a different SAT
(supervisory audio tone), sends this back correctly to the
base station and thus maintains connection.
The mobile is not in test mode.
Make the general test preparations. The channel type
must be To analog TC.
Initiate a call with
{MOBILE}
in an analog traffic channel).
Change the scroll variable for SAT frequency.
Press
in the basic test mask. In this way
{EXECUTE}
signaling adopts the new SAT frequency.
Test Results
Mobile could send back new SAT correctly: connection does
not break off, basic test mask continues to show results in
analog sector. Exception: if NO SAT is selected, connection
must break off after approx. 5 s.
Frequency of SAT can be read from AF frequency meter in
DUPLEX mask (return to basic test mask with
Mobile could not send back new SAT correctly: connection
usually breaks off.
IS-136 MS
or
(the mobile must be
{CELL.}
+
[AUX]
{DATA}
).
10
10-23
Need help?
Do you have a question about the IS-136 MS and is the answer not in the manual?
Questions and answers