General Steps Of Stove Installation - J. A. Roby STRATO Instruction Manual

Hide thumbs Also See for STRATO:
Table of Contents

Advertisement

General steps of stove installation

1)
Read the entire installation manual before installing
and using your stove.
2)
Choose a place to install your cookstove. Read the
sections
about
localisation of stove over the floor protection, and
clearance to combustible materials. Once you have
decided where to install the stove, mark the center of
chimney on the floor.
o To make sure the vertical center of the chimney, use
a plumb line to mark on the floor.
3)
Check if it is possible to pass chimney without
damaging the structure of your house. You might have
to move the location of the stove while keeping the
minimum clearance. If you have to cut a joist, be sure
to respect the building code in effect to keep the
structural integrity of your house.
Note: This appliance has to be connected to:
A type factory-built chimney approved ULC S629
with 6 inches diameter (15.24 cm);
• A conforming masonry chimney of 6 inches
diameter (15.24cm) with qualified internal lining
4)
Install the chimney following the manufacturer
instructions.
5)
Put the stove on the floor aligned vertically with the
center of chimney, and trace the 4 sides of the stove
vertically on the floor. Please remove the stove.
PR_I029/2023-08-24-EN
dimensions
of
floor
protection,
6)
Mark the dimensions of protection panel on the floor.
The edge clearance of the sides and the back is
8 inches (20.3 cm). At the front, it must be 18 inches
(45 cm) in Canada, measured from the front door.
7)
Install the floor protection according to the mark. (It
must be non-combustible)
8)
Put the stove on the protection floor. Respect the edge
clearance that you have set at step 6 and the centre of
the chimney as well. We recommend to fix the stove to
the floor with bolt in the slots in the stove legs made for
this purpose. If you have a pedestal, use the holes
made for this purpose.
9)
If you have an outside air inlet you must use 4 inches
(10.16 cm) flexible aluminum pipe. The pipe must be
sealed with thermal resistant sealant
10) Install the chimney connector from the stove. The pipe
must be attached with at least 3 screws, to the collars
of the stove and the chimney, also each joint of
connection.
Note:
• The single wall chimney connector must be 6 inches
diameter (15,25 cm) and have a minimum thickness
of 24 gauge (0.025 inches 0.64 mm).
• Do not use galvanised steel chimney connector.
Revision: 7
18

Advertisement

Table of Contents
loading

Table of Contents