Instructions for the installer

7. INSTALLING THE APPLIANCE

7.1
Positioning
This is a class 1 (B2) and 3 (A, B1)appliance.
The following operation requires building and/or carpentry work, therefore
it must be carried out by a skilled technician.
Installation can be carried out on various materials such as masonry,
metal, solid wood or plastic laminated wood as long as they are heat
resistant (T 90°C).
7.2
Heights for type A installation (empty base)
A
DISTANCES
MINIMUM
MAXIMUM
The supporting strips
to the base in order to support the weight of the product and its use.
A
B
866 mm
630 mm
866 mm
650 mm
must be of the appropriate size and secured
C
L
50 mm
904 mm
-
-
H
750 mm
-