Adaptation To Different Types Of Gas - Smeg PVA96-3 Instructions For Use Manual

Table of Contents

Advertisement

Instructions for the installer

9. ADAPTATION TO DIFFERENT TYPES OF GAS

Before carrying out the following operations, disconnect the appliance
from the electricity supply.
The appliance is preset for natural gas NG (2H) at a pressure of 1 kPa. In
the case of operation with other types of gas the burner nozzles must be
changed and the minimum flame adjusted on the gas taps. To change the
nozzles, proceed as described below.
9.1
Replacement of nozzles on the hob
1 Extract the pan stands and remove all the caps and flame-spreader
crowns;
2 Unscrew the burner nozzles with a 7 mm socket wrench;
3 Replace the burner nozzles according to the type of gas to be used
(see point "9.2 Burner and nozzle characteristics table").
4 Replace the burners in the correct position.
21