Installation with the flexible hose must be carried out so that the length of
the piping does not exceed 2 metres fully extended; make sure that the
hoses do not come into contact with moving parts and that they are not
crushed in any way.
8.1
Use a pressure regulator and make the connection on the gas cylinder
following the guidelines established by the regulations in force.
Make sure that the feed pressure complies with the values indicated in the
table at point "9.2 Burner and nozzle characteristics table".
8.2
Caution – This appliance may only be installed and operated in rooms
permanently ventilated in accordance with current regulations. For proper
operation of a gas appliance it is essential for the air necessary for
combustion of the gas to be able to flow naturally into the room. Air must
flow directly into the room through openings in its outside walls. This
(these) opening (s) must have a free passage cross-section of at least 100
cm2, or 200 cm2 for appliances not equipped with gas safety device.
These openings must be constructed so that they cannot be obstructed
indoors or outdoors, and should preferably be close to the floor on the side
opposite to the combustion gas discharge point. If it is not possible to
make the openings in the room where the cooker is installed, the
necessary air may be taken from an adjoining room, proveded it is not a
bedroom or a room with fire risk.
8.3
Combustion gases may be discharged by means of hoods connected to a
flue with reliable natural draught, or a fan extraction system. An effective
extraction system requires careful design by an authorised specialist, and
must comply with the regulation distances and positions. After installation,
the engineer must issue a certificate of compliance.