The following boxed messages are displayed in the center of the screen.
WARNING
FAN HAS STOPPED!!!
ABNORMAL CORRECTION DATA
"RANGE OVER"
"RANGE OVER" is displayed in the portion of
the gauge that displays the percentage.
H
V
H
V
LIST.
Conditions:
Countermeasures: A fan operation check is required. Please contact a
Conditions:
Countermeasures: Please review the amount of correction for the
Conditions:
+ 6 5 %
+ 6 5 %
RANGE OVER
+ 6 5 %
Countermeasures: Please review the amount of correction for the
One or more of the fans located within the projector
has stopped.
The projector power will be switched off in about 15
seconds. (Error code E0)
service person.
The amount of correction for the various adjustment
items has become abnormally large. Left as is, a
burden will be placed upon the projector; therefore,
measures have been taken to protect the projector.
The data of the adjustments which were performed
when the message was displayed have been set to
0%, (i.e., the data are not stored).
Depending on the circumstances, the projector power
might be switched off about 2 seconds after the
message appears. (Error code F8)
various adjustment items.
Also, check with service personnel to ensure that the
projector is placed properly.
This message might be displayed at the time of the
CONVERGENCE, FOCUS (EDGE SEPARATE),
and WHITE-BAL adjustments. Should this display
appear, further increases or decreases in the amount
of correction will not reflect a change of the data on
the screen.
various adjustment items.
The various data correlate with the adjustment
(setting) data of ALIGNMENT, FOCUS (EDGE
ALL), and COLOR TEMP., and changes to this data
result in changes to the range over which "RANGE
OVER" occurs.