INSTALLATION
CLEARANCES TO COMBUSTIBLES
The clearances listed are MINIMUM distances. Measure the
clearance to both the appliance and the chimney connector.
The farthest distance is correct if the two clearances do
not coincide. For example, if the appliance is set as Indicated
in one of the diagrams but the connector is too close, move the
stove until the correct clearance to the connector is obtained.
This appliance may be Installed only with the clearances as
shown in the situations pictured. Do not combine clearances
from one type of installation with another in order to
achieve closer clearances.
This unit can be installed on a solid combustible surface like a
wood floor. This unit can also be installed directly on carpeting
or vinyl when the bottom pedestal cover plate (provided vwth
unit) is installed.
Use the minimum clearances shown in the diagrams below;
U27-NG1 & U27-LP1 Clearances
A Side Wall to Unit
7-1/2"/190 nim
B Back Wall to Unit
3"/76 mm
E Side Wall to Unit
4-1/2-7114 mm
U27-NG1 & U27-LP1 Reference Dimensions
C Floor to Flue Centerline
23" / 584 mm
D Side Wall to Flue Centerline
20-1/2"/521 mm
914 mm/36"
Minimum
Minimum ceiling
height is 36"/914
mm from top of unit.
LOCATING YOUR ULTIMATE GAS STOVE
When selecting a location for your stove, ensure that the clearances
listed above are met as well as ensuring that there is adequate
accessibility for servicing and proper operation.
For Vent Termination requirements, see page 10.
This appliance is Listed for bedroom installations when used witti a
Listed Millivolt Thermostat. Some areas may have further require¬
ments, check local codes before installation.
This appliance is Listed for Alcove installations, maintain minimum
Alcove clearances as follows, minimum ceiling height of 64"(1.6m),
minimum width of 48"(1.2m) and a maximum depth of 36"(0.9m).
A) Cross Corner
B)
Flush with Wall/Alcove
C) Flat on Wall Corner
D) Flat on Wail
U27-1 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater