INSTALLATION
14) This unit can be installed on a solid combus-
tible surface like a wood floor as well as on
carpeting.
INSTALLATION
CHECKLIST
1) Check Clearances to Combustibles. Refer to
the "Clearance to Combustibles" section.
2) Install flueing. Refer to the "Flueing"
section.
3) Make gas connections. Refer to the "Gas
Connection" section.
Test the pilot. Must be as per diagram in the
"Pilot Adjustment" section.
4) If necessary, convert NG to LPG. Refer to
the "Conversion from NG to LPG" section
5) Test Gas Pressure. Refer to the "Gas Pipe
Pressure Testing" section.
6) Install log set. Refer to the "Log Set
Installation" section.
7) Install Front Door. Refer to the "Front Door
Installation" section.
8) Test for flue spillage (draft test). Refer to the
"Test for Flue Spillage" section.
9) Install Optional Features. Refer to the
following sections where applicable:
a. Optional Wall Thermostat
b. Optional Remote Control
10) Final check. Refer to the "Final Check"
section.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fir-
ing correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning or that results in
damage is not the responsibility of the manu-
facturer.
6
CLEARANCES TO
COMBUSTIBLES
The clearances listed below are MINIMUM
distances. Measure the clearance to both the
appliance and the chimney connector. (The
farthest distance is correct if the two clear-
ances do not coincide.) For example, if the
appliance is set as indicated in one of the figures
but the connector is too close, move the stove
until the correct clearance to the connector is
obtained.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when
the bottom pedestal cover plate (provided with
unit) is installed.
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.
Use the minimum clearances shown in the
diagrams below for all installations.
Clearances
A Side Wall to Unit
B Back Wall to Unit
E Side Wall to Unit
Reference Dimensions
C Back Wall to Flue Centerline 10-3/4" / 273 mm
D Side Wall to Flue Centerline 20-1/2" / 520 mm
F Side Wall to Flue Centerline 11" / 280 mm
M i n i m u m
height is 36" / 914 mm
from top of unit.
If further reduced clear-
ances are needed, ob-
tain requirements for
construction of a pro-
tected wall from your
local building authori-
ties and their allowable
reductions of the listed
clearances.

DRAFT DIVERTER

This heater has a draft diverter built in. It must
not be altered, obstructed, or blocked in any way,
and the unit must be installed so that the draft
diverter is in the same atmospheric pressure
zone as the combustion air inlet to the burner.
This heater must be properly connected to a
flueing system.
7-1/2" / 190 mm
WARNING: Operation of this heater when not
connected to a properly installed and main-
6" / 155 mm
tained flueing system can result in carbon
2" / 50 mm
monoxide (CO) poisoning and possible death.
This heater is a flued appliance and must be
connected to a chimney/flue in accordance with
the installation codes.
Note:
The rear pedestal cover plate must
always be fitted for safety. Electrical
connections inside.
Flueing Requirements
A100 mm diameter flue is required. For cosmetic
or aesthetic purposes 6" outer flue can be used
as long as an approved inner flue is installed.
Fasten but do not penetrate the inner sleeve
ofthe flue when tightening the screw.
The minimum flue required is 3.3m from floor
level.
Follow all flueing manufacturer's requirements
and local building codes or AS5601-2004.
Regency F38-2 Freestanding Gas Stove