Regency U39-NG11 Owners & Installation Manual

Regency U39-NG11 Owners & Installation Manual

Freestanding
Table of Contents

Advertisement

Quick Links

Ultimate™ U39 Freestanding Gas Stove
MODELS: U39-NG11 Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour: CSA 2.17-2017
919-914
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
U39-LP11 Propane
Installer: Please complete the details on the back cover
ANSI Z21.88-2017
and leave this manual with the homeowner.
CSA 2.33-2017
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
www.regency-fire.com
04.24.19

Advertisement

Table of Contents
loading

Summary of Contents for Regency U39-NG11

  • Page 1 Owners & Ultimate™ U39 Freestanding Gas Stove Installation Manual www.regency-fire.com MODELS: U39-NG11 Natural Gas U39-LP11 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 ® of a woodstove, at the flick of a switch. The models U39-NG11, and U39-LP11 of this series has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Panel Glass Replacement ...........43 Gas Connection ............24 Fan Maintenance ............44 High Elevation ..............24 DC Sparker battery replacement .........44 Valve replacement ............45 Parts Main Assembly ............46 Burner & Log Assembly ..........47 Door Assembly ............48 Warranty Warranty ..............49 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 4: Dimensions

    9 13 16 " (250mm) ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 5: Copy Of Safety Label For U39 Gas Stove

    1.6" WC/C.E. (0.40kPa) B 6" /150mm Fonctionnant à une altitude entre 0 et 2000 pi : Model U39-NG11: Factory Equipped for Altitude 0-2000 ft. E 2" /50mm Min. Ceiling Height from top of unit / Min. Plafond Orifi ce size Dimensions de l’orifi...
  • Page 6 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 7: Before You Start

    ANY SAFETY SCREEN, GUARD, OR CIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS BARRIER REMOVED FOR SERVICING OR CLOTHING IGNITION. AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 8: Important Message

    This appliance may only be installed see "Rigid Pipe Venting Arrangements" section in an aftermarket permanently located, for the required vent arrangements. If installed Fuels: U39-NG11 is approved for use with natural manufactured (mobile) home, where into a manufactured home the unit must be gas.
  • Page 9: General Safety Information

    Use the minimum clearances shown in the diagrams c. Wall Thermostat below: d. Remote Control e. Safety Screen U39-NG11 & U39-LP11 Clearances f. Louver Installation A Side Wall to Unit 7-1/2" / 190 mm g. 1-AA battery into DC spark box B Back Wall to Unit 6"...
  • Page 10: Manufactured Mobile Home Additional Requirements

    The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent, venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG11, and U39- LP11, have been tested and listed as direct vent heater systems by Intertek. If converting a Class-A Metal Chimney to a Direct Vent system, see instructions in "Converting a Class-A Metal Chimney...
  • Page 11: Exterior Vent Terminal Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 12: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    ” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: The listed manufacturers may have other lengths not shown on this chart, which would also be approved.
  • Page 13 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency U39-11 ULTIMATE™ Freestanding Gas Stove...
  • Page 14: Rigid Pipe Venting Systems

    Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products ® International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 14 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 15: Installation Precautions

    Venting Systems that have been designed and tested for use with Mobile Homes the U39-NG11, and U39-LP11. The warranty will The shaded areas in the diagram below show be voided and serious fire, health or other safety all allowable combinations of vertical runs with...
  • Page 16 4 feet total vertical and max. 4 feet total horizontal. Please note min. 1 foot between 90 elbows is required. Lengths do not include elbow indicated Vent restrictor position A (fully open). Refer to the “Venting Arrangement” section. 16 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 17: Dv Stove Horizontal Vent Kit Installation

    When using snow blowers, of the starter collar on the unit. make sure snow is not directed towards vent termination area. Note: if the centerline cannot be met, the adjustable sections will have to be cut. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 18 8. Cut the 4" dia. flex liner to the desired size. to the elbow. Seal with Mill-Pac and secure with 3 of the #8 x 1/2" screws (black). Pipe seams facing down. 18 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 19: Dura-Vent Termination Kit

    Planning Your Dura-Vent Dura-Vent Horizontal Termination Kit Installation You will require the following components with Wall Thimble (required for combus- your new Regency Direct Vent Freestanding Gas ® tible walls) There are two basic types of Dura-Vent Direct Stove. Please review your product to make sure you Vent System installations: horizontal termination have everything you need.
  • Page 20: Dura-Vent Horizontal Terminations

    7" diameter hole code requirements. is acceptable. Note: Riser Vent is only for use in above grade terminations. Diagram 3a Diagram 2 20 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 21: Dura-Vent Vertical Terminations

    2. Frame the hole as shown in diagram 10. attach with screws provided. Apply decorative brass or chrome trim if desired. See diagram Diagram 5 Diagram 7 Diagram 10 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 22: Cathedral Ceilings

    2/12-7/12 5-1/2" a mastic. 7/12-12/12 6-3/4" 12/12-24/12 7-1/2" Diagram 13 24/12+ 12-1/2" Diagram 12 22 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 23: Converting Aclass-A Metal Chimney To A Direct Vent System

    Insure that you are in fact, drilling into the metal on the chimney. Twist-lock the Termination Cap onto the Adaptor. (Diagram 3 and 4). Diagram 2 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 24: System Data

    Log Set: Ceramic fiber, 7 per set. 7. The connection between the appliance and the Retro Connector may be completed with sections of black direct vent pipe, together with an adjustable length. 24 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 25: Conversion From Ng To Lp

    4. Open pedestal door and remove the chain from door which will allow door to 20. The burner aeration should be set to fall. 10. Unscrew the pilot orifice with the allen 1/2" open for LP. key and replace with the LPG pilot See aeration adjustment details in the 5. R emove 2 screws that secure the front orifice in the kit. manual. door to the unit. One screw is on the left hand side and the other on the right hand 11. Reinstall new burner orifice LPG 21. Check for proper flame appearance and side. (Left side shown). stamped #51 and tighten. glow on logs. Installer Notice: These instructions must be left with the appliance. 04.24.18 919-504 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 26: Conversion To Lower Btu Rating

    Btu information. 9. Check for gas leaks. 10. Check inlet and outlet pressures. 11. Check operation of flame control. Check for proper flame appearance and glow on logs. 26 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 27: Sit 829 Valve Description

    Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty. Note: Aeration Adjustment should only be performed by an authorized Regency ® Installer at the time of installation or service. To adjust the aeration: use the Allen key to turn the turning gear which will adjust the air shutter.
  • Page 28: Log Set Installation

    Place Rear Log A on the two pins on the rear log support. Place the Left Top Log D on the pin on Log B and on top of the cut-out on Log A. Pins on Rear Log Support Cutout 28 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ® 918-039b 04.05.18...
  • Page 29 10. Next, take the white Platinum Ember material (provided) and gently separate the layers until you have a fi ne layer to place onto the Embaglow (steel wool type media). Platinum Embers Notch 918-039b 04.05.18 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 30 If there is any fl ame hesitation, check that area for any blockage of the burner port. A)02-65 B)02-56 E)02-45 C)02-44 918-039b 04.05.18 30 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 31: Log Set Installation

    Place Rear Log A on the two pins on the rear log support. Place the Left Top Log D on the pin on Log B and on top of the cut-out on Log A. Pins on Rear Log Support Cutout Regency U39-11 ULTIMATE™ Freestanding Gas Stove ® 919-939 10.15.18...
  • Page 32 10. Next, take the white Platinum Ember material (provided) and gently separate the layers until you have a fi ne layer to place onto the Embaglow (steel wool type media). Platinum Embers Notch 32 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ® 919-939 10.15.18...
  • Page 33 12. Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other. If there is any fl ame hesitation, check that area for any burner port blockage. 919-939 10.15.18 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 34: Wiring Diagrams

    Caution: Ensure that the wires do Wiring errors can cause not touch any hot surfaces and are improper and dangerous away from sharp edges. operation. 34 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 35: Optional Wall Thermostat

    2. Remove 2 screws that secure the front door on an interior wall. to the unit. One screw is on the left hand side and the other on the right hand side. (Left side Regency offers an optional programmable ® shown).
  • Page 36: First Fire

    8. Hook up remote receiver to wire marked 'receiver' which will be located on the bottom of the appli- ance. This remote control requires coding. See remote control instructions for details. 36 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 37: Copy Of Lighting Plate Instructions

    Mettre le bouton de commande de gaz en position OFF pour éteindre la veilleuse. Pour économiser le carburant, éteignez la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 38: Automatic Convection Fan Operation

    Blower: ADJUSTING FLAME HEIGHT Regency gas appliances use high tech blowers ® to push heated air farther into the room. It is not Your heater has an adjustable flame to tailor the look unusual for the fan to make a "whirring"...
  • Page 39: Proflame Gtmf System Operating Instructions

    Figure 3 - Remote Control Display in Fahrenheit and Celsius Thermostat Room OFF/ON/SMART Temperature Set Point Temperature/Level/State Flame ON Aux ON Fig. 2: Transmitter LCD display. Figure 2 - Transmitter LCD Display Figure 4 - Remote Control Display Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 40 Up or Down Arrow Keys until the desidered set temperature is displayed on the LCD screen of the Transmitter (Fig. 7). Flame Off Flame Level 1 Flame level 5 Flame Level Maximum Figure 7 Figure 6 - Smart Flame Function 40 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 41 Receiver. When the batteries are replaced the “beep” will be emitted from the Receiver when the ON/OFF Key is pressed (See Initialization of The System). Figure 10 Figure 11 Figure 13 Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 42: Maintenance Maintenance Instructions

    The heater is finished in a heat resistant paint P R I O R TO O P E R AT I N G T H E Top View of pilot flame and should only be refinished with heat resistant paint (not with wall paint). Regency uses ® APPLIANCE.
  • Page 43: Log Replacement

    5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement door from an authorized Regency ® dealer only, and follow our step-by-step instructions for replacement. The...
  • Page 44: Fan Maintenance

    5. Lift fan off of the 2 pins, tip back and pull through firebox opening. Disconnect the green ground wire from the right side of the fan as soon as accessible. 44 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 45: Valve Replacement

    13. Remove the valve tray and replace. 14. Reverse Steps 1-11 to complete. Stepper motor wire 6. If the fan is installed–disconnect the "COM" wire from the valve. 7. Disconnect the DC spark generator wires from the valve. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 46: Main Assembly

    Flex Pipe 3" ID *Not available as a replacement part. Hose Clamp 910-233 Thermodisc - Fan Auto/On/Off Mounting Bracket - Thermodisc 630-021 Fan Access Panel (SEPARATE ILLUSTRATION ON GLASS DOOR FRONTS) 46 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 47: Burner & Log Assembly

    733-987 Conversion Kit LP 911-029 Valve/Remote Wiring Harness 911-093 120 Volt Power Cord (10 foot extension) 910-233 Fan Thermodisc 911-137 Pilot Clip 100. 910-373 Pilot/On/Off Extension Knob *Not available as a replacement part. Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 48: Door Assembly

    732-570 Door Gasket Kit 105. Ceramic Paper 107. 936-243 Glass Gasket 111. Door Frame Fibre Paper 208. 940-325/P Wrap Glass 209. 732-020 Door Mounting Bracket *Not available as a replacement part. 48 | Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 49: Warranty

    Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 50: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty 50 | Regency U39-11 ULTIMATE™...
  • Page 51 Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: February 2019 Regency Gas Products Warranty Regency U39-11 ULTIMATE™ Freestanding Gas Stove ®...
  • Page 52 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 53 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 56 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ U38-39 Video Printed in Canada Regency is a trademark of FPI Fireplace Products International Ltd. ® © Copyright 2019, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Ultimate u39U39-lp11

Table of Contents