Regency E21 Owners & Installation Manual

Gas insert zero clearance kit 530-936
Hide thumbs Also See for E21:

Advertisement

Owners &
Installation
Tested by:
Warnock Hersey:
© Copyright 2004, FPI Fireplace Products
International Ltd. All rights reserved.
U20/E21 GAS INSERT
ZERO CLEARANCE KIT
PLEASE KEEP THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WARNING:
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property damage.
Refer to this manual. For assistance
or additional information consult an
authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in
the vicinity of this or any other
appliance.
Installation and service must be
performed by an authorized installer,
service agency or the gas supplier.
Fireplace Products International Ltd.
6988 Venture St., Delta, B.C.
Canada, V4G 1H4
Masport Head Office - Australia
54 Boundary Rd. Braeside
P.O. Box 553
Mordialloc 3195
Ph. (03) 9586-7777
Fax. (03) 9586-2980
908-037
KIT # 530-936
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any
! ! ! ! !
appliance
Do
not
! ! ! ! !
electrical switch: do not
use any phone in your
building.
Immediately call your
! ! ! ! !
gas supplier from a
neighbour's
Follow the gas supplier's
instructions.
If you cannot reach your
! ! ! ! !
gas supplier, call the fire
department.
Australian Heating Distributors
10/46 James St.,
Guildford, Western Australia 6055
Masport Head Office - New Zealand
1-37 Mt Wellington Hwy.Panmure,
P.O. Box 14349
Auckland 6.
Ph. (9) 570-9009
Fax. (9) 527-1294
touch
any
phone.
01/15/04

Advertisement

Table of Contents
loading

Summary of Contents for Regency E21

  • Page 1: For Future Reference

    U20/E21 GAS INSERT ZERO CLEARANCE KIT KIT # 530-936 Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY What to do if you smell gas: Improper installation, adjustment, alteration, service or maintenance Do not try to light any ! ! ! ! ! can cause injury or property damage.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS U20/E21 GAS INSERT ZERO CLEARANCE KIT CONTENTS PAGE Listings & Code Approvals ..........3 Specifications ............... 3 General Information ............. 4 Parts ..................4 Clearances to combustibles ..........4 Locating Your Fireplace ............. 5 Framing ................5 Kit Assembly .................
  • Page 3: Listings & Code Approvals

    Check with your local building code agency before you begin your installation to ensure compliance with local codes, including the need for "permits" and follow-up inspections. If any problems are encountered regarding code approvals, or if you wish clarification on any of the instructions contained here, contact your local dealer. Specifications U20/E21 Gas Insert Zero Clearance Kit...
  • Page 4: General Information

    This kit consists of factory built parts that require minimal Included with Kit: assembly to form the Zero Clearance box for the U20/E21 Main Body Assembly (5 pieces) Gas Insert. The Zero Clearance box can then be fixed into a Faceplate Top Insulation framed combustible construction, and a standard "B-vent"...
  • Page 5: Locating Your Fireplace

    4) The appliance may be enclosed above standoffs on the cabinet but the clearances stated on the b-vent chimney must be maintained. U20/E21 Gas Insert Zero Clearance Kit...
  • Page 6: Kit Assembly

    4) Attach the top assembly, with the top flanges on the outside of the Sides and Back panels. 5) Do not install the Zero Clearance Top Louver until the U20/E21 Insert has been installed. U20/E21 Gas Insert Zero Clearance Kit...
  • Page 7: Venting

    Instructions in U20/E21 Installation Manual. clean and in good working order. When an existing masonry chimney is unlined and local experience Install stove insert as per U20/E21 Installation Manual, indicates that gas condensation may be a problem see also page 8.
  • Page 8: Insert Installation

    Zero Clearance box, both are located on the left hand the Insert Instruction manual. Use the gas line cover side of the U20/E21 Insert. See "Gas Supply Line" on plate that is included with the Zero Clearance box. page 9 and "Electrical Supply" on page 9.
  • Page 9: Optional Outside Combustion Air Supply Installation

    The suggested way to install the gas supply line is as follows: run 1/2" (9.5 mm) NPT gas line to the left side of the framed opening. (See U20/E21 installation instructions for additional information).
  • Page 10: Faceplate & Trim Installation

    Self-adhesive Wire Clip 8) The power cord should be run behind the faceplate Wires to For Gas panel from the U20/E21 to electrical outlet box. Fan Switch Connection Connectors 9) Place top insulation in behind the top faceplate as in the diagram.
  • Page 11: Zero Clearance Top Louver

    The height at which the mantle must be installed above the top louver depends on the depth of the mantle. If the mantle is to be painted, use a heat resistant paint to prevent discolouration. U20/E21 Gas Insert Zero Clearance Kit...
  • Page 12 Printed in Canada...