Installation Checklist; Clearances To Combustibles; Locating Your Regency Gas Stove; Combustion And Ventilation Air - Regency FireGenie FG37-NG Manual

Hide thumbs Also See for FireGenie FG37-NG:
Table of Contents

Advertisement

INSTALLATION
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.)
be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
INSTALLATION
CHECKLIST
1) Check Clearances to Combustibles (page 6),
location of unit (page 6) and fluing require-
ments (pages 6-9).
2) Install fluing: Check all fluing requirements,
pages 8-12.
3) Make gas connections, page 12. Test the
pilot. Must be as per diagram, pages 15 &
22.
4) If necessary, convert from NG to LPG (page
13).
5) Install log set, page 15.
6) Install Front Door Front, page 16.
7) Test Gas Pressure, page 17.
8) Install Louvres, page 17.
9) Install optional Remote Control, page 18.
10) Final check, page 18.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fir-
ing correctly and operation fully explained
to customer.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
6
LOCATING YOUR
REGENCY GAS STOVE
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility
for servicing and proper operation.
For Flu Termination requirements, see page 7.
This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows,
minimum ceiling height of 1.7m, minimum width
of 1.0m and a maximum depth of 0.9m.
A)
Cross Corner
B)
Flush with Wall/Alcove
C)
Flat on Wall Corner
This appliance may be installed only with the
clearances as shown in the situations pictured.
Do not combine clearances from one type of
installation with another in order to achieve
closer clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with unit)
is installed.
Use the minimum clearances shown in the
diagrams below:
FG37-NG & FG37-LPG Clearances
A Side Wall to Unit
190 mm
B Back Wall to Unit
76 mm
E Side Wall to Unit
114 mm
FG37-NG & FG37-LPG
Reference Dimensions
C Floor to Flue Centerline
635 mm
D Side Wall to Flue Centerline 521 mm
Minimum ceiling height is 914 mm from top
of unit.
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
D)
Flat on Wall
CLEARANCES TO COM-
BUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance and
the chimney connector. The farthest distance is
correct if the two clearances do not coincide.
For example, if the appliance is set as indicated
in one of the diagrams but the connector is too
close, move the stove until the correct clearance
to the connector is obtained.
The Regency Room
Sealed System (Hori-
zontal Termination Kit
COMBUSTION AND
VENTILATION AIR
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside the
room is not required.