Rear vent direct vent freestanding gas stove
Table of Contents

Advertisement

NSTALLATION
Wall Penetration
Heat Shield
(round - insjde)
Pipe Length
/
Wall
Thimble
Cover
Vinyl Siding Shield
(Optional)
V
Riser Vent
^
Backing Plate
.
3
^.
^Tt
Riser Vent
Front
Diagram 5
Wall Penetration
Heat Shield
(square - outside)
c)
d)
5)
If Installing termination on a siding covered wall, a vinyl
siding standofforfurring strips must be used to ensure that
the termination is not recessed into the siding. Dia. 5.
pipe so that the screw heads
are hidden on the final instal¬
lation. Apply sea!ant"Mi!i-Pac"
to inner pipe and high temp
silicone sealant or "Miil-Pac"
„ '
to outer pipe on every joint,
to inner
Pipe
Hint: Apply sealant to female end.
__
I
I
Before connecting the vent pipe to the vent termination,
slide the black decorative wall thimble cover over the vent
pipe, then slide the Wall Penetration Heat Shield (Part #
946-202) over the vent pipe. Dia. 5.
Slide the appliance and vent assembly towards the wall
carefully Inserting the vent pipe into the riser vent terminal
assembly. It is importantthat the vent pipe extends into the
Riser Vent Backing Plate a sufficient distance so as to
result in a minimum pipe overlap of 1-1/4 inches. Secure
the connection between the vent pipe and the vent cap by
attaching the two sheet metal strips extending from the
Riser Vent Backing Plate into the outer wall of the vent
pipe. Use two aluminum screws provided to connect the
strips to the pipe section. Bend any remaining portion of
the sheet metal strip back towards the vent cap and cut off
any excess, it will be concealed by the decorative wall
thimble cover. See diagram 7.
8)
Slide the decorative wall thimble up to the wall surface
being careful not to scratch the paint. See diagram 7.
Riser Vent
Front
Diagram 6
Riser Vent
Backing Plate
Wall Penetration
Heat Shield
(square - outsic i
not required for
non-combustible walls
7)
Install the Backing Plate into the wall pene¬
tration heat shield and attach using 4 screws.
Dia. 6,
6)
Take the Riser Vent terminal and separate the Backing
Plate from the Riser Vent Front by removing 8.screws as
shown in diagram 6.
8)
Connect a!! pipe sections to unit and install into wall:
a)
Measure pipe length required and cutto length. Hint use
the cut end of the 6-5/8" dia. outer pipe at the ventterminal
end.
b)
Push the pipe sections completely together, the minimum
pipe overlap is 1-1 /4". Secure all outer pipe joints by using
at least two screws. Locate the screws at the bottom of the
9)
Back outside: Apply sealant to the 4" inner flue and slide
the Riser Vent Front into the Backing Plate and fasten with
8 screws.
10) Seal around the outer edge of the Riser Vent Backing
Plate.