INSTALLATION
WIRING DIAGRAM
Ground X"
Green
Neutral.
White
(120V AC)
Uve
ID
Pilot I i i-i'
/tesembly
ON
'f \
OFF
Lo-10—Or
'CPl
f;4o
Rotary Speed
Control
Black
Minimum Convection
Air Temp. Switch
_^To
"■niermocouple IN
Ignitor
Remote .
..
(Piezo)
Receiver;
:
..
(Optional)
'
L i
(Millivolt) [hz^J
Remote Sender
(Optional)
Black
' ■ &I.T" Valve
Red
Thermostat J
(Optional)
(Millivolt)
«•
..R^.
Burner
OFF
THERMOSTAT
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes:
1)
Clocking the appliance to ensure the correct firing rate (rate noted on label) at 15 minutes.
2)
If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to
stabilize.
CAUTION
Any alteration to the product that causes sooting or carboning that results In damage to the exterior facia is not the
responsibility of the manufacturer.