INSTALLATION
LOUVER INSTALLATION
OPTIONAL WALL THERMOSTAT
1) Attach the top & bottom louvers to the side stove panel
using 2 screws per side.
OPTIONAL REMOTE CONTROL
Use the Regency Remote Control Kit (Part # 910-358/P)
approved for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held transmitter, a
receiver and a wall mounting plate.
1)
Choose a convenient location on the wall to install the
receiver and the receptacle box (protection from extreme
heat is very important). Run wires from the fireplace to that
location, use Thermostat Wire Table.
2)
Connect the wires as per the wiring diagram on page 18.
CAUTION
Do not connect the millivolt remote
control wires to the 120V wires.
3)
Install a 9V alkaline battery in both the receiver and the
transmitter. Install the receiver and its cover In the wall.
Switch the hand held remote transmitter to "remote" mode.
The remote control is now ready for operation.
A wall thermostat may be installed if desired. Connect the
wires as per the wiring diagrams. Note that the wires are
connected to the "TH" on the gas valve. Use chart below to
determine the maximum wire length:
Note: Preferable if the thermostat is installed on an interi¬
or wail.
Regency offers a programmable thermostat but any CSA,
ULC or UL approved millivolt thermostat, 250-750 millivolt
rated non-anticipator type thermostat may be used.
'
CAUTION
"
Do not connect the millivolt wall
thermostat wires to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
1
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.