What to expect from a factory set system
The system is fully programmable using the procedure in the next section. However, we have setup a
few things so you will be able to test the console immediately the wiring is complete.
General Cancel is programmable, but we have set it to cancel all the stops. If you wish to remove some
stops from GC simply rescope it during commissioning.
Commissioning process:
Before beginning.
Please read these instructions to familiarise yourself with the process. If you have any questions, please
don't hesitate to contact us for more information.
Make sure you have wired the system as per the provided connector list. If you have a generic
block of divisional pistons, these may be used in any order and for divisional pistons, cancels, or
simple reverser pistons.
Please note that general pistons MUST be wired in the correct order with General Piston 1 input wired
to General Piston 1, and without gaps. This will ensure correct operation of the piston sequencer.
Set = hold set control and press the control/piston
Scope = hold set and scope controls, press the control/piston
Note : Tutties and general cancel may only be set/scoped while in commissioning mode.
Process
1. Turn on the input labelled "Commissioning Mode" by briefly pressing the button you installed
earlier. Commissioning mode edits a special memory that is used to store all the defaults. The
display will show 0
2. Scope General Cancel to the stops to be affected by the capture system (usually all
stops on the console) Note: This is new as in previous systems there was no option to
scope the GC.
3. Scope the general pistons (any order is fine) to the stops to be affected by general pistons and
stepper/sequencer.
4. Scope the pistons in each division to the stops they should change for that division.
5. Scope any reverser pistons to the single stop they should reverse (MUST be a single stop ONLY
or it will act as a normal piston)
20 |
P a g e
Need help?
Do you have a question about the CapLite 64 and is the answer not in the manual?