Page 1
For complete instructions refer to instruction manual for EP104 as well as other documentation included in the delivery FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN, +46 435 77 95 00, support@faac.se...
Page 2
QUICK GUIDE DAAB CONTROL UNIT EP104 V4.07 Quick guide for commissioning of swing gates • Prerequisites The electrical installation is complete and drive units should be disengaged from the drive arm. Operate only one drive unit at a time and start with drive unit 1. The type of motor power in C202 is set to 0, 3x400V with neutral. Limit switches must be of encoder type.
Page 3
QUICK GUIDE DAAB CONTROL UNIT EP104 V4.07 • Comissioning of drive unit 2 Preparation: Open gate leaf 1 and set L001 to 0 to maintain the gate leaf in open position. Set C033 to 5, Service mode. Direction of movement: Set L002 to 4, hold-to-run without limit switches. Check that the drive arm mounting is moving in the right direction while pressing OPEN or CLOSE button on the controll board.
Need help?
Do you have a question about the DAAB EP104 V4.07 and is the answer not in the manual?
Questions and answers