Page 1
For complete instructions refer to instruction manual for EP104 as well as other documentation included in the delivery FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN, +46 435 77 95 00, support@faac.se...
Page 2
QUICK GUIDE DAAB CONTROL UNIT EP104 V4.07 Quick guide for commissioning of swing gates • Prerequisites The electrical installation is complete and drive units should be disengaged from the drive arm. Operate only one drive unit at a time and start with drive unit 1. The type of motor power in C202 is set to 0, 3x400V with neutral. Limit switches must be of encoder type.
Page 3
QUICK GUIDE DAAB CONTROL UNIT EP104 V4.07 • Comissioning of drive unit 2 Preparation: Open gate leaf 1 and set L001 to 0 to maintain the gate leaf in open position. Set C033 to 5, Service mode. Direction of movement: Set L002 to 4, hold-to-run without limit switches. Check that the drive arm mounting is moving in the right direction while pressing OPEN or CLOSE button on the controll board.