• Important! For the safety of people, it is important that all the instructions be carefully observed.
• Incorrect installation or incorrect use of the product could cause serious harm to people.
• Carefully read the instructions before beginning to install the product and keep them for future reference.
The symbol
indicates notes that are important for the safety of persons and for the good condition of the automated system.
• The symbol
draws your attention to the notes on the characteristics and operation of the product.
Before attempting any work on the control unit (connections, maintenance), always turn off power.
Install, upstream of the system, a differential thermal breaker with adequate tripping threshold,
Connect the earth cable to the relevant terminal (see fig.5).
Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical disturbance, use separate
sheaths or a screened cable (with the screen earthed).
Manufacturer: FAAC S.p.A.
Address:
Via Benini,  - 40069 Zola Predosa BOLOGNA - ITALY
Declares that: The E24 control unit
• ·conforms to the essential safety requirements of the following EEC directives
2006/95/EC Low Voltage Directive
2004/108/EC Electromagnetic Compatibility Directive
Additional note:
Bologna, 01 March 2008
4
TECHNICAL SPECIFICATIONS
Primary power feed
from mains
Secondary power
feed
Power absorbed
from mains
Max. load
for motor
Power feed
for accessories
Accessories
max. current
Battery charge
current
Operating ambient
tempeature
Protective fuses
Function logics
"step-by-step" Semiautomatic, Automatic
with reverse during pause, Automatic
step-by-step, Safety devices automatic,
Safety devices step-by-step automatic,
"b" Semiautomatic, mixed logic "bC",
Dead-man, Automatic with timer function
Work time
Programmable (from 0 to 4 minutes)
Pause time
Programmable (from 0 to 4 minutes)
Motor power
Motor speed
E124 control unit – rapid guide

CE DECLARATION OF CONFORMITY

This product underwent tests in a typical uniform configuration
(all products manufactured by FAAC S.p.A.).
with switching power feed
230/5 V~ - 50/60 Hz
24 Vdc - 6 A max.
(min. 20 Vdc. - max. 28 Vdc.)
stand-by = 4W
max. ~ 400 W
7 A
24 Vdc
24Vdc max. 500 mA
BUS-2EASY max. 500 mA
80 mA
(-20 - +55) °C
All self resetting
Semiautomatic, Automatic,
Programmable on 50 levels
Programmable on 0 levels
WARNINGS
The Managing Director
A.Marcellan
Connector inputs
Terminal board inputs
Terminal board outputs
Programming
These instructions are to be considered
as a rapid guide for installation. The complete
instructions can be downloaded at the following
address: www.faacgroup.it
To access PROGRAMMING FROM PC, use the
X-COM module or connect the USB cable to the
dedicated connector and consult the dedicated
instructions.

Switching feeder, Battery,
Decoder/Minidec/RP , X-COM, module
XF433/868, USB
BUS-2EASY, Inputs from IN to IN5 (see
par. 5), Travel limit device, Encoder.
Flashing lamp, Motors, Electrical lock,
OUT, OUT2 (programmable), power feed
to accessories
st and 2° lev. with 3 keys (+, -, F) and LCD
display.
3rd lev. with P .C. connected via USB or with
X-COM module.

Advertisement

Table of Contents
loading

Summary of Contents for FAAC E124

  • Page 1: Ce Declaration Of Conformity

    Via Benini,  - 40069 Zola Predosa BOLOGNA - ITALY Declares that: The E24 control unit • ·conforms to the essential safety requirements of the following EEC directives 2006/95/EC Low Voltage Directive 2004/108/EC Electromagnetic Compatibility Directive Additional note: This product underwent tests in a typical uniform configuration (all products manufactured by FAAC S.p.A.). Bologna, 01 March 2008 The Managing Director A.Marcellan TECHNICAL SPECIFICATIONS Primary power feed with switching power feed...
  • Page 2: Description Of Components

    LAYOUT AND COMPONENTS OF E124 DL15 DL16 DL17 DL19 DL18 DL20 DL13 DL10 DL11 DL12 DESCRIPTION OF COMPONENTS LED OPERATION DL16 SIGNALLING LED FOR “SW1” PUSH-BUTTON (R1 PUSH-BUTTON) Description DL17 SIGNALLING LED FOR “SW2” PUSH-BUTTON (R2 PUSH-BUTTON) (contact closed) (contact open) SIGNALLING LED FOR “SW3” PUSH-BUTTON (SETUP PUSH-BUTTON)
  • Page 3: Electrical Connections

    Max load 24Vdc - 500mA CONNECTION OF TRADITIONAL SAFETY DEVICES The following table shows the programming operations of the With the E124 control unit, you can use both dip-switch inside the transmitter and the BUS 2-EASY photocells traditional photocells (N.C. contact with relay) and/or receiver.
  • Page 4 6.2.2 MEMORY STORAGE OF BUS-2EASY ACCESSORIES CONNECTOR J13 – XF MODULE RAPID CONNECTION Cut power to the board. Connect the two cables of the BUS-2EASY accessories to the red terminal-board J3 (any polarity will do). Power the board, taking care to first connect the plug J of the main power supply (coming from the switching feeder) and then, connector J2 of any batteries.
  • Page 5: Function Logics

    FAAC 412, 413/415, 770, 390 (see default column ). Configures parameters with DEFAULT values corresponding to an installation with operators FAAC 391 (see default column 2). Configures parameters with DEFAULT values corresponding to an installation with operators FAAC S700H...
  • Page 6 0 second steps, up to the maximum value of minutes. FINAL CLOSING THRUST: = active = excluded REVERSING STROKE AT OPENING: = active = excluded SOFT TOUCH: (function active with FAAC operators only) = active = excluded PRE-FLASHING: = no pre-flashing = pre-flashing before every movement. = pre-flashing before a closing motion. = pre-flashing before an opening motion.
  • Page 7 Display Function Default Default Default Default TRAVEL-LIMIT STOP AT OPENING: he use of travel limit stops at opening enables us to indicate the point after which the equipment search for the mechanical stop point or to immediately stop the automated system. = no travel limit device at opening for both leaves = searches for stop point of leaf  and 2 = stops movement of leaf  and 2 = searches for stop point of leaf ...
  • Page 8: Alarm And Error Signals

    Display Function Default Default Default Default ASSISTANCE REQUEST – CYCLES COUNTER (coupled to the next two functions): When the number of cycles settable with the following functions is reached, this facility pre-flashes for 8 sec. (in addition to the pre-flashing already set with the function) before every movement.