Table 4- 2.
Symptom
9. Transmitted data con-
tains the wrong parity.
10. Transmitted data con-
tains no STX.
Digital Circuits, Sytnptom Troubleshooting Chart (Continued)
a.
b.
Check Procedure
Connect the 402 -2 Test Set to
J 1 of the Terminal Unit and
place the character select
switch to 3.
On the display,
enter the characters Y and ~
in the first and second character
slots of the first line and depress
the XMIT key.
Observe that the
test set lamp readout indicates
LS~OO
110 10.
Ente r X and
*
in the first and
second character slots of the
first line, and depress the
XMIT key.
Observe that the
test set lamp readout indicates
LS~OOllOl1.
a.
Connect the 402-2 Test Set to
J 1 of the Terminal Unit and
place the character select
switch to 1.
Enter the ETX
code and depress the XMIT key.
Observe that the test set lamp
readout indicates
LS~
100000 1.
Corrective Action
If the readout indication is
incorrect, replace A 12.
If the readout indication is
correct, perform check b.
If the readout indication is
incorrect, replace A 12.
If the readout indication
. is correct, the trouble is
not in the Terminal Unit.
If the indication on the
lamp readout is incorrect,
replace A 12 board.
If the indication on the
lamp readout is correct,
the trouble is not in the
Terminal Unit.