7.1 Firmware Error Message

Message
Laser Tube Error Laser tube is overheat press any key to stop
Cause
V30 laser tube responses the over-temp signal for a period of time,
and firmware recognizes the laser tube is over temperature.
Solution Check the temperature is down to normal level , turn off the
machine,wait for the laser tube be cooled.
Invalid file, check output file or reset command mode. press any key
Message
to stop
Cause
PCL command error
Solution Check the output file command
Message
WARNING! SmartGUARD fire alarm system is activated,please
reboot machine
Cause
Flame detected by SmartGUARD
Solution Reboot the machine
Message
WARNING! Emergency stop is activated, please free the emergency
stop to continue next job
Cause
Emergency stop is activated
Solution Release the emergency stop button
Message
Please install the Auto Focus pin first before performing the auto
focusing or focus tuning
Cause
Auto Focus pin is not installed
Solution Check if the autofocus pin is installed
Message
HPGL Command Error Command: Address: Please press any key to
stop
Cause
HPGL command of printing file is not defined.
Solution Check the HPGL command