CONNECTING AND CONFIGURING EXTERNAL EQUIPMENT
5.4 Sensor input
Man_instr_ai71_ai70_r1
Port configuration
The Long Range port has the following default settings:
Baud Rate
4800
The baud rate is configurable from 1200 to 57600. Refer
Configuring External Serial Ports, pages 72 and 80.
Input sentences
Sentence
LRI
LRF
Output sentences
Sentence
Long-range function
LRF
identification
LR1
Long-range response
LR2
Long-range response
LR3
Long-range response
Physical location
Sensor1 is installed on P2, pins 18 - 22, Sensor2 is installed on
P2, pins 6 - 10 and Sensor3 is installed on P1, pins 6 - 10.
Port configuration
The sensor inputs Sensor1, Sensor2 and Sensor3 are equivalent
and the default settings are as follows:
Baud Rate
4800
Parity
Bits
N
8
Content
Long-range interrogation
Long-range function identification
Content
Transmission interval
When LR response sent
When LR response sent
When LR response sent
When LR response sent
Parity
Bits
N
8
Stop Bit
1
Stop Bit
1