IMPORTANT! If the MMA welding mode is selected, the welding voltage will only be avail-
able after a 3-second time lag.
2
3

HotStart function

To obtain optimum welding results, it will sometimes be necessary to adjust the HotStart
function.
Benefits
-
-
-
See the "Setup menu: level 2" section for details on setting the available welding parame-
ters.
I (A)
Example of HotStart function
Setting examples:
HCU = 100
The HotStart current is adequate to the actually set welding current I
The HotStart function is not activated.
HCU = 170
The HotStart current is 70 % higher then the actually set welding current I
The HotStart function is activated.
60
MMA welding mode
Use the adjusting dial to set the desired welding current.
The welding current value is shown in the left-hand digital display.
All the parameter set values that have been set using the adjusting dial are saved until
the next time they are changed. This applies even if the power source is switched off
and on again in the meantime.
Start welding
Improved ignition, even when using electrodes with poor ignition properties
Better fusion of the base material in the start-up phase, meaning fewer cold-shut de-
fects
Largely prevents slag inclusions
Hti
150
100
HCU
I
1
0,5
Legend
Hti
HCU
I
1
Function:
during the specified hot-current time (Hti),
the welding current I
Hotstart current HCU.
t (s)
To activate the HotStart function, the Hots-
tart current HCU must be > 100.
1
1,5
Hot-current time, 0-2 s,
factory setting: 0.5 s
HotStart current, 0-200 %,
factory setting 150 %
Main current = set welding current
is increased to the
1
.
1
.
1

Advertisement