Service Faults - Manitowoc Indigo NXT IDT0300A Installation, Operation And Maintenance Manual

Hide thumbs Also See for Indigo NXT IDT0300A:
Table of Contents

Advertisement

Available languages

Available languages

Section 5
Problem
Low ice capacity.

Service Faults

In addition to the standard safety controls,
such as the high pressure cutout, your
Manitowoc ice machine features built-
in service faults which will stop the ice
machine if conditions arise which could
cause a major component failure.
Before calling for service, re-start the ice
machine using the following procedure:
1.
Press the power button. The display
reads "Off". Press the power button
again, and the display reads "Making
Ice".
A. If a service fault has stopped the
ice machine, it will restart after a
short delay. Proceed to step 2.
B. If the ice machine does not
restart, see "Ice machine does not
operate" on page 55.
Part Number 000014141 Rev 11 12/23
Possible Cause
Water inlet valve filter screen
is dirty.
Incoming water supply is shut
off.
Water inlet valve stuck open
or leaking.
The condenser is dirty.
High air temperature entering
condenser.
The harvest assist air
compressor is not functioning.
Remove the water inlet valve
and de-scale the filter screen.
Open the water service valve.
Press the power button and
turn off the ice machine, if
water continues to enter
water trough, replace the
water inlet valve.
Clean the condenser.
Refer to minimum/maximum
air temperature chart for your
model on page 14.
Call for service.
2.
Allow the ice machine to run to
determine if the condition repeats.
A. If the ice machine stops again, the
condition has repeated. Call for
service.
B. If the ice machine continues to
run, the condition has corrected
itself. Allow the ice machine to
continue running.
Troubleshooting
To Correct
57

Advertisement

Table of Contents
loading

Table of Contents